Optix OSN8800 TN55TOX 8-Channel 10G Tributary Service Processing Board
  • The Optix OSN8800 TN55TOX single board belongs to the tributary class of single boards, which realizes the inter-conversion between 8-channel 10GE LAN/10GE WAN/STM-64/OC-192/OTU2/OTU2e/FC800/FC1200 service optical signals and 8-channel ODU2/ODU2e/ODUflex electrical signals.


Consultation hotline:
18529092692
Product Introduction

Products

Huawei OTN Tributary Service Board OSN8800 TN55TOX Technical Parameters Description

The TOX board belongs to the tributary category, realizing the interconversion between 8-channel 10GE LAN/10GE WAN/STM-64/OC-192/OTU2/OTU2e/FC800/FC1200 service optical signals and 8-channel ODU2/ODU2e/ODUflex electrical signals.

The application of TOX single board in WDM system is shown in Figure 1.

Figure 1 Application of TOX single board in WDM system

OSN8800 TN55TOX价格

Table 1 Customer-side service encapsulation paths supported by single boards

Single boardCustomer-side servicesBackplane-side services encapsulated as
TN55TOX/TN56TOXSTM-64/OC-192/10GE WAN/OTU2ODU2
OTU2eODU2e
10GE LANODU2/ODU2e
TN56TOXODU2/ODU2eODU2e
FC800ODU2/ODUflex

Optix OSN8800 TN55TOX 8-Channel 10G Tributary Service Processing Board Functions and Features

The TOX single board supports functions and features such as electrical layer crossing.

TOX single board functions and features, as shown in Table 1.

Table 1 TOX Single Board Functions and Features

Functions and FeaturesDescription
Basic Functions

TOX supports the conversion of signals:

  • 8 x 10GE LAN/10GE WAN/STM-64/OC-192/OTU2/FC8008 x ODU2

  • 8 x 10GE LAN/OTU2e/FC12008 x ODU2e

  • 8 x FC8008 x ODUflex

Customer Side Service Types

STM-64/OC-192: SDH/SONET service at 9.95 Gbit/s

10GE LAN: Ethernet service at 10.31 Gbit/s

10GE WAN: Ethernet service at 9.95 Gbit/s

OTU2: OTN service at 10.71 Gbit/s

OTU2e: OTN service at 11.1Gbit/s

FC800: SAN service at 8.5 Gbit/s

FC1200: SAN service at 10.51Gbit/s

Description:

Only the TN56TOX supports FC800 and FC1200 services.

Crossover Capability

The TOX supports 8 ODU2/ODU2e/ODUflex signals to cross-schedule services with the cross board via the backplane bus.

Description:

Only the TN56TOX supports ODUflex scheduling.

OTN Function.
  • Supports mapping of each 10G signal to the backplane side ODU2/ODU2e interface.

  • Mapping processing meets ITU-T G.709, G.Sup43 recommendations, using ITU-T G.709 recommended frame format and overhead processing.

  • Supports the PM function of the ODU2 layer on the backplane side.

  • Support SM and TCM function when TOX veneer accesses OTN service.

ESC Function

Supported when the client side accesses OTU2/OTU2e services.

Error Correction CodingFEC coding is supported on the client side only when accessing OTU2/OTU2e, in accordance with ITU-T G.709 recommendations.
Performance Monitoring and Alarm Monitoring
  • Provides BIP8 byte monitoring (burst mode), which can locate line faults.

  • Provides the following monitoring functions: laser bias current monitoring, laser operating temperature monitoring, optical power monitoring, etc.

  • Supports OTN performance monitoring and alarm monitoring.

  • With Ethernet RMON monitoring function (10GE LAN).

ALS Function

Supported on the client side when accessing non-OTN services.

PRBS Function

The PRBS function is supported on the client side.

Description:

The PRBS function is supported on the client side only when accessing STM-64/OC-192, OTU2, and OTU2e services.

LPT Function.

The LPT function is supported only when the service type of the customer side is 10GE LAN.

Test frame functionTest frame function is supported when the customer side accesses 10GE LAN service and the "Port Service Mapping Path" is "MAC Transparent Mapping (10.7G)".
Delay MeasurementThe single board supports delay measurement. It can measure the bidirectional delay of ODUk layer between two tributary boards, and the delay data is displayed on the network management.

Description:

When the client side accesses OTU2/OTU2e services, delay measurement is not supported.

IEEE 1588v2

TC mode, TC+OC mode, BC mode and OC mode are supported when the client side accesses 10GE LAN service and the "Port Service Mapping Path" is "MAC Transparent Mapping (10.7G)".

Description:

  • TN55TOX: Only RX1/TX1 and RX2/TX2 support processing IEEE 1588v2 clock signals.

  • TN56TOX: All ports support processing IEEE 1588v2 clock signals.

Physical Layer Clocking
  • When 10GE LAN service is accessed on the client side and the port service mapping path is "Bit Transparent Mapping (11.1G)", synchronous Ethernet pass-through is supported, synchronous Ethernet processing is not supported.

  • When the customer side accesses 10GE LAN service and the port service mapping path is "MAC transparent mapping (10.7G)", synchronous Ethernet processing is supported and synchronous Ethernet pass-through is not supported.

Layer ASONSupport

Ethernet service encapsulation

Bit transparent mapping (11.1G), MAC transparent mapping (10.7G)
Port MTU

1518~9600 bytes, i.e. supports Jumbo frames up to 9600 bytes.

Description:

When the "Port Service Mapping Path" is "Bit Transparent Mapping (11.1G)", port MTU setting is not supported.

Protection Mode
  • ODUk SNCP protection is supported.

  • Supports client-side 1+1 protection.

  • Supports branch SNCP protection.

Description:

When the scheduling granule is ODUflex, branch SNCP protection is not supported.

Description:

Branch SNCP protection is supported only when the customer side accesses OTN services, SDH/SONET services, and 10GE WAN services.

LoopbackWavelength Division Side-
Customer SideInternal LoopbackSupported
Outer LoopbackSupported

Supported Protocols or Standards

Protocols or standards for pass-through (no performance monitoring)

IEEE 802.3ae

ITU-T G.707

ITU-T G.782

ITU-T G.783

NCITS FIBRE CHANNEL PHYSICAL INTERFACES (FC-PI)

NCITS FIBRE CHANNEL LINK SERVICES (FC-LS)

NCITS FIBRE CHANNEL FRAMING AND SIGNALING-2 (FC-FS-2)

NCITS FIBRE CHANNEL BACKBONE-3 (FC-BB-3)

NCITS FIBRE CHANNEL SWITCH FABRIC-3 (FC-SW-3)

NCITS FIBRE CHANNEL - PHYSICAL AND SIGNALING INTERFACE (FC-PH)

GR-253-CORE Synchronous Optical Network (SONET) Transport Systems: Common Generic

This producttechnical parametersandproduct characteristicsby Shenzhen Guihang Network Technology Co., Ltd (www.opticaltrans.com), reproduced please retain.Huawei SDH Optical Transmission Equipment,SDH Transmission EquipmentSales Tel: 18529092692 Welcome to contact us!

Huawei TN55TOX Purchase Price_Product Description_Hardware Description_Technical Parameters_Product Characteristics-Huawei SDH transmission equipment sales

Supply Optix OSN8800 TN55TOX Quote_Agent Price_Sales Manufacturer_Product Supplier-Huawei SDH transmission equipment sales

Online Ordering
Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML