OptiX PTN1900Performance and Capacity

Attribute

Feature Name

Technical Parameters and Performance Indicators

Performance

Packet switching capacity

TN71CXP/TN72CXP: 10 G bit/s (10 G bit/s in both outgoing and incoming directions)

TN73CXP: 80 G bit/s (80 G bit/s in both outgoing and incoming directions)

Packet processing capacity

15 Mpps (TN71CXP/TN72CXP)

120 Mpps (TN73CXP)

Main control board and switching network board inversion performance CXP reversal performance

No loss of board pulling and manual reversal services

Ethernet private line services

Number of Ethernet private line services on the whole machine

1024 (TN71CXP/TN72CXP)

4096 (TN73CXP)

Ethernet private network service

Number of whole machine Ethernet private network services (i.e., number of Ethernet private network service VSIs)

256 (TN71CXP/TN72CXP)

512 (TN73CXP)

Number of MAC address forwarding table entries supported per VSI

65534 (TN71/72/73CXP)

Number of dynamic MAC address forwarding table entries supported by the entire machine

65536 (TN71/72/73CXP)

Number of static MAC address forwarding table entries supported by the entire machine

2048 (TN71/72/73CXP)

ATM service

Whole machine ATM UNI-UNI service ( ATM local service)

512 (TN71/72/73CXP)

( ATM local service shares resources with ATM remote service)

Whole machine ATM UNI-NNI service ( ATM remote service)

1024 (TN71/72/73CXP)

(Shared resources between ATM local service and ATM remote service)

Number of whole machine local service ATM connections

1024 (TN71/72/73CXP)

(Including VCC connection and VPC connection.)

(Shared resources between local service ATM connections and remote service ATM connections)

Number of remote service ATM connections for the whole machine

2048 (TN71/72/73CXP)

(Including VCC connections with VPC connections. )

(Local service ATM connections share resources with remote service ATM connections)

Number of whole ATM remote transmitting services

256 (TN71/72/73CXP)

IMA Number of IMA groups in the whole machine

664 (TN71CXP/TN72CXP)

96 (TN73CXP)

CES Operations

Number of whole machine CES operations

2048 (TN71CXP/TN72CXP)

536 (TN73CXP)

IP over PW

Number of whole machine IP over PW

UNI->PW: 63

V-UNI->PW: 1024 (TN71CXP/TN72CXP)

L3VPN Service

Maximum number of FIB table entries supported by the whole machine

1024 (TN71CXP/TN72CXP)

20480 (TN73CXP)

Number of VRFs for the whole machine

64 (TN71/72/73CXP)

Maximum number of EBGP Peers supported by the whole machine

512

VLAN sub-interfaces Number of VLAN subinterfaces in the whole machine

1792

DHCP Relay

Number of DHCP Server IP addresses

8 (TN71/72/73CXP)

(Each service supports 8 DHCP Server IP addresses)

Maximum number of DHCP Relay relay hops

16 (TN71/72/73CXP)

ARP

Maximum number of static ARP table entries for the whole machine

512

Maximum number of dynamic ARP table entries per port

2048

ML-PPP

Number of ML-PPP groups supported by the whole machine

128 (TN71CXP/TN72CXP)

64 (TN73CXP)

Total number of PPP links in the whole machine

256 (TN71/72/73CXP)

ML-PPP group member link number range

1~16 (TN71/72/73CXP)

MPLS Tunnel Number of static unidirectional MPLS Tunnel for the whole machine

2048 (TN71CXP/TN72CXP)

4096 (TN73CXP)

(Dynamic/static MPLS Tunnel shared resources.)

Number of dynamic unidirectional MPLS Tunnel for the whole machine

1024 (TN71CXP/TN72CXP)

2048 (TN73CXP)

(Dynamic/static MPLS Tunnel shared resources.)

Number of Static Bidirectional MPLS Tunnel for the whole machine

1024 (TN71CXP/TN72CXP)

2048 (TN73CXP)

(Dynamic/Static MPLS Tunnel shared resources. One static bidirectional MPLS Tunnel is equivalent to two static unidirectional MPLS Tunnels.)

QinQ Link

Number of QinQ Links on the whole machine (network side)

256 (TN71/72/73CXP)

IP Tunnel

2 (TN71CXP/TN72CXP)

Number of IP Tunnel on the whole machine

256

GRE Tunnel

2 (TN71CXP/TN72CXP)

Number of GRE Tunnel

256 GRE Tunnel

PW

Number of PWs on the whole machine

2048 (TN71CXP/TN72CXP)

4096 (TN73CXP)

Ethernet Service OAM

Maximum number of whole machine MDs

64

Maximum number of whole machine MA

1024

Maximum number of whole MEPs

2048

ATM OAM Number of ATM OAM for the whole machine

2048 (TN71/72/73CXP)

MPLS Tunnel OAM Number of MPLS Tunnel OAMs

1024 (TN71CXP/TN72CXP)

2048 (TN73CXP)

PW OAM Number of PW OAMs on the entire machine

1024 (TN71CXP/TN72CXP)

2048 (TN73CXP)

BFD

Number of whole machine BFDs

256 (TN71CXP/TN72CXP)

0 (TN73CXP)

LPT

Number of point-to-point LPTs for the whole machine

16

Reversal time

Customer side notification within 4 seconds

TPS Protection

(TN71CXP/TN72CXP)

Number of TPS protection groups in the whole machine

2

MPLS ring protection Number of protection rings in the whole machine

4

Number of nodes supported per ring 2 to 32
Number of virtual nodes supported per ring 32

MPLS Tunnel APS

Number of Whole 1+1/1:1 MPLS Tunnel APSs

512 (TN71CXP/TN72CXP)

1024 (TN73CXP)

1+1/1:1 MPLS Tunnel APS Rewind Time

<50 ms

(using 3.3ms FFD detection cycle)

PW APS/MC-PW APS

Number of 1:1 PW APS/MC-PW APS in the whole machine

512 (TN71CXP/TN72CXP)

1024 (TN73CXP)

1:1 PW APS/1:1 MC-PW APS inversion time

<50ms

(using 3.3ms FFD detection cycle)

Offload protection

Number of 1:1 Offload protection groups for the whole machine

64 (TN71CXP/TN72CXP)

1:1 Offload protection reversal time

<50 ms

(using BFD detection with a period of 10 ms)

LAG/MC-LAG

Number of LAGs/MC-LAGs in the machine

24

Number of members per LAG

16

Switching time

  • Link interruption in both directions, LAG protection inversion time is less than 500 milliseconds
  • Link unidirectional interruption, LAG protection inversion time less than 3.5 seconds
Description:
  • For GE electrical interfaces, the LAG protection inversion time is less than 1 second.
  • For FE electrical interfaces, the LAG protection inversion time is less than 500 milliseconds.
LMSP/MC-LMSP Number of complete LMSPs/MC-LMSPs

20

Description:

The TN73CXP does not support MC-LMSP.

Inversion time

<50 milliseconds

VRRP (TN71CXP/TN72CXP)

Number of whole VRRP

64

Rewind time

200 ms

(with BFD detection)

802.1X authentication

Maximum number of legitimate users supported by the whole machine

64/16 (control domain and L3VPN service domain/management domain)

Maximum length of 802.1x messages supported (Bytes)

1450 (TN71CXP/TN72CXP)

1900 (TN73CXP)

QoS

Number of DiffServ domains on the whole machine

8

Number of whole-machine flow classifications

4096

Number of CARs for whole-machine flow classification (double-bucket CARs)

4096

Number of ACLs

4096

CAR/Shaping Accuracy (Granularity)

64Kbps


Supply OptiX PTN1900_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply OptiX PTN1900_Troubleshooting_Installation and Testing_Technical Specifications_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板