The technical specifications of the OptiX OSN2500 subrack are shown in Table 1.
| Dimensions | Weight |
|---|---|
| 447mm (W) x 295mm (D) x 472mm (H) | 17kg (net weight of the subrack without veneer and fan) |
The maximum power consumption of the OptiX OSN subrack is shown in Table 2.
| Subrack type | Maximum power consumptiona | Insurance capacity | Typical Configuration | |
|---|---|---|---|---|
| Typical Power Consumption |
Single Board Configuration at Typical Power Consumption |
|||
| OptiX OSN2500 Common Subracks | 400W | 15A | 222W |
|
| OptiX OSN2500 Enhanced Subracks | 650W | 20A | 313W |
|
| a: The maximum power consumption of the subrack indicates the maximum power consumption configuration that the subrack can withstand and the maximum heat dissipation capability that the subrack has. Typical configurations for real-world applications consume much less power than this value. | ||||
The maximum power consumption of the cabinet in full configuration is equal to the sum of the maximum power consumption of all the subracks configured in the cabinet and the maximum power consumption of the other configurations of the cabinet.
For transmission equipment, power consumption is essentially all converted to heat consumption. Therefore, the heat consumption (BTU/h) value of the equipment can be converted with the power consumption (W) value, the conversion formula is: heat consumption (BTU/h) = power consumption (W) ÷ 0.2931 (Wh).