- TN54NS4/TN57NS4/TN58NS4:
-
In OptiX OSN 8800 T64 Enhanced Subrack/OptiX OSN 8800 T32 Enhanced Subrack/OptiX OSN 8800 T16 Subrack, the NS4 veneer supports line mode and trunk mode. When working in line mode, the OptiX OSN 8800 T64 Enhanced Subrack must be configured with USXH+UXCT veneer; the OptiX OSN 8800 T32 Enhanced Subrack must be configured with UXCH/UXCM veneer; and the OptiX OSN 8800 T16 Subrack must be configured with TN16UXCM veneer.
- In the OptiX OSN 8800 T64 Universal Subrack/OptiX OSN 8800 T32 Universal Subrack/OptiX OSN 8800 Universal Platform Subrack, the NS4 veneer board only supports trunk mode.
-
- TN56NS4:
-
In the OptiX OSN 8800 T64 Enhanced Subrack/OptiX OSN 8800 T32 Enhanced Subrack/OptiX OSN 8800 T32 General Purpose Subrack/OptiX OSN 8800 T16 Subrack, the NS4 veneer boards support both Line Mode and Trunk Mode. When working in line mode, the OptiX OSN 8800 T64 enhanced subrack must be configured with the USXH+UXCT veneer; the OptiX OSN 8800 T32 enhanced subrack/OptiX OSN 8800 T32 general-purpose subrack must be configured with the UXCH/UXCM veneer; and the OptiX OSN 8800 T16 subrack must be configured with the TN16UXCM veneer .
The TN56NS4 supports line mode on the OptiX OSN 8800 T32 Universal Subrack only if the "OptiX OSN 8800 T32 Universal Subrack Supports 100G Line Card Capability License" is configured.
- In OptiX OSN 8800 T64 Universal Subrack/OptiX OSN 8800 General Purpose Platform Subrack, NS4 single board only supports trunk mode.
-
Types
| Type | Wavelength Division Side Fixed Optical Module | FEC Code |
|---|---|---|
| T01 | C-band-tunable wavelength-ePDM-QPSK (HFEC)-PIN | HFEC |
| T11 | C-band-tunable-wavelength-ePDM-QPSK (SDFEC, NRZ)-PIN | SDFEC |
| SDFEC | C-band-tunable-wavelength-ePDM-QPSK (SDFEC, CRZ plus)-PIN | SDFEC |
| T19 | C-band-tunable-wavelength-ePDM-QPSK (SDFEC, CRZ)-PIN | SDFEC |
| T21 | C-band-tunable-wavelength-ePDM-QPSK (HFEC2, RZ)-PIN | HFEC2 |
| T28 | C-band-tunable wavelength-ePDM-QPSK (HFEC2, CRZ plus)-PIN | HFEC2 |
| T29 | C-band-tunable-wavelength-ePDM-QPSK (HFEC2, CRZ)-PIN | HFEC2 |
| Type | Wavelength Division Side Fixed Optical Module | FEC code |
|---|---|---|
| T11 | C-band-tunable wavelength-ePDM-QPSK (SDFEC, NRZ)-PIN | SDFEC |
| Type | Wavelength Division Side Fixed Optical Module | FEC Code |
|---|---|---|
| T01 | C-band-tunable wavelength-ePDM-QPSK (HFEC)-PIN | HFEC |
| T09 | C-band-tunable-wavelength-ePDM-QPSK (HFEC)-PIN | HFEC |
| HFEC T31 | C-band-tunable-wavelength-ePDM-QPSK (SDFEC2, wDCM-Enhanced)-PIN | SDFEC2 |
| SDFEC2 | C-band-tunable-wavelength-ePDM-QPSK (SDFEC2)-PIN | SDFEC2 |
| T61 |
C-band-tunable-wavelength-ePDM-QPSK (SDFEC2, wDCM)-PIN |
SDFEC2 |
| T65 | C-band-tunable wavelength-ePDM-QPSK (SDFEC2, wDCM-Metro)-PIN | SDFEC2 |
|
Description:
T65 type of single board is applied in metro scenario, WDM side module transceiver wavelength needs to be the same, and relay variable wavelength is not supported. |
||
| Type | Wavelength Division Side Fixed Optical Module | FEC code |
|---|---|---|
| T41 | C-band-tunable wavelength-ePDM-QPSK (HFEC PLUS)-PIN | HFEC PLUS |
| T51 | C-band-tunable-wavelength-ePDM-QPSK (SDFEC2)-PIN | SDFEC2 |
| T61 |
C-Band - Tunable Wavelength - ePDM-QPSK (SDFEC2, wDCM) - PIN |
SDFEC2 |
| T65 | C-band-tunable wavelength-ePDM-QPSK (SDFEC2, wDCM-Metro)-PIN | SDFEC2 |
|
Description:
T65 type of single board is applied in metro scenario, WDM side module transceiver wavelength needs to be the same, and relay variable wavelength is not supported. |
||
Difference between versions
- Function:See Functions and Features for details.
Single Board FEC Code TN54NS4 SDFEC/HFEC/HFEC2 TN56NS4 SDFEC TN57NS4 SDFEC2/HFEC TN58NS4 SDFEC2/HFEC PLUS - Appearance and pluggable slots:
TN58NS4 is single-slot, other NS4 veneers are dual-slot. See panel for appearance differences, and see Pluggable Slots for differences in pluggable slots.
- Indicators:
Metrics vary by version. See NS4 metrics.
Alternative Relationships
| Original Veneer | Replacement Veneer | Replacement Description |
|---|---|---|
| TN54NS4 | TN56NS4/TN57NS4 | TN56NS4/TN57NS4 can be created as "54NS4" or "54NS4(REG)" in the network management, and replace TN54NS4 without software upgrade. The replacement board has only the functions of TN54NS4. Description: TN56NS4: Substitution is possible only when both the transmitting and receiving veneers use SDFEC coding. TN57NS4: can be substituted only when both the transmitting and receiving veneers use HFEC coding and the veneer types are the same. |
| TN56NS4 | None | -No |
| TN57NS4 | TN58NS4 | TN58NS4 can be created as "57NS4" on the network management and replace TN57NS4, no software upgrade is required for the replacement.TN58NS4 occupies 1 physical slot, and TN57NS4 occupies 2 physical slots.TN58NS4 needs to be placed in the right side of the slot occupied by the original TN57NS4 when it replaces TN57NS4. When TN58NS4 replaces TN57NS4, it needs to be inserted in the right slot of the slot occupied by the original TN57NS4, and the free physical slot cannot be inserted with a single board. The replacement board only has the function of TN57NS4. Explanation: The replacement is possible only when both the transmitting and receiving veneers use SDFEC2 coding and the veneer types are the same. |
| TN58NS4 | None | - |