18529092692

Home >> News
News
OSN3500 host software package issue causes error in querying the status of a multiplexed segment
| 2025-11-21|Back

Problem Description

In a bureau, when an engineer performs protection subnet status on a multiplexed segment ring grouped by OSN3500 devices, he finds that no matter whether he queries the multiplexed segment status in the Network Element Manager or in the protection subnet network management prompts the error: Command Error (which indicates that the command is not supported by the veneer), Error Code: 38751.

The host version is 5.21.17.31.

Webmaster version is V2R5C01b01cSPC007.

Alert message
None
Processing

1. First, use the command line :cfg-get-rmsstate to query the state of the multiplexing segment of the network element and find that it can be queried, so it is suspected that the problem is with the network administrator.

2, and then in the network management query other Metro 1000 and other devices found to be able to query normally, no error, query other OSN 3500 devices (version is: 5.21.12.43/5.21.13.47) can also be queried normally, no error, to rule out the network management problem.

3, suspect that the network management and host coordination problems, return to the EMS.log log analysis can be found in the network management to return such an error: NSCMD_CFG_GET_MSSPR_SWSTA_02, corresponding to the host to send the command is: cfg-get-rmsstate-new

4. having the site directly issue this command prompts:

:cfg-get-rmsstate-new:1;
failed! cmd:0x853f error:0x975f NSERR_BDRSP_BAD_CMD

The OSN 3500 device's multiplexing segment protocol is on the cross-board, so to query the multiplexing segment status, you need to query the cross-board; the host of the R7 supports this command, so the problem should be that the cross-board doesn't support this command!

5, query the site of the cross board version 2.14, this version is supporting the R2 host, the original site think that we should be ready to replace the SXCS cross board, in order to save trouble only the host upgraded to the R7 without upgrading the cross board. After upgrading the cross board to version 6.31, the problem was solved.

Root Cause

1、Network management problem

2, host problem

3、Network management and host with the problem

4、Other problems

Recommendations and Summary

OSN3500 transmission equipment is required to version strong matching, so when upgrading the host, cross, line and other single boards to upgrade all matching!


Sales optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板