Huawei SS62COA reports EDFA aging alarm when used with osn3500
| 2025-11-21|Back

Problem Description
An operator opens 2.5G service between osn2500 at two points A and B. Because of the distance, 62COA is used for amplification. After testing, it is found that 62COA reports EDFA aging alarms WORK_CUR_OVER and OUT_PWR_ABN, and the service is normal.
Alarm information
WORK_CUR_OVER, OUT_PWR_ABN
Processing
1, the field test line receiving light is -42dBm, after the COA output is -26dBm, it can be seen that the COA has amplified the line signal, and the business is normal, so it can be concluded that the single board is normal.
2, query the manual found that the 62COA switching gain of the maximum 15dB, and -26dBm for the 62COA default locking optical power, so suspected that because of the default locking gain is too large, resulting in the EDFA module alarms. Just adjust the locking power of 62COA a little smaller to eliminate the alarm.
3, consult the R & D know OSN equipment used on the 62COA is borrowed from the 4.0 platform board, in the 5.0 platform does not have a corresponding command to set the locking power, you can connect the COA to the 2500 + equipment using :cfg-set-coalockpower command to set the locking power can be. Alternatively, you can use the command :ptp:bid,ee,1,1,01,2c,a5 to set the locking power, in which the 6th and 7th parameters are the target power (the command here is to set the locking power to -30dBm, i.e., it is displayed as: -300, and the corresponding parameter is set as: 01,2c). You can use the :ptp:bid,12,ee,1 command to query the current output optical power locked value, the return value is: ncmd 0 : 65 12 ee 01 01 00 fa ff where the penultimate and third return value is the current locked power, which is -25dBm in this command.
Root cause
1, 62COA single board failure.
2. Incorrect setting of the single board parameters causes the single board to report an alarm.
Suggestions and Summary
1, it is recommended that the R & D can give 5.0 platform to set the locking power of the relevant host command, in order to open the bureau tuning test.
2, ptp command to set the locking power that is the output power of the COA veneer, the scene set remember to check before setting and COA output connected to the receiving veneer receiving light range, so as not to cause failure.
3, set the parameters to follow the following principles: set the locking power is not too close to the default locking power. For example, the COA input is -41dBm, the gain is 15dB, the default locking power is -26dBm, in fact, the locking power can be set to -27dBm to eliminate the alarm, but if the line power drops the alarm will reappear, so it is best to combine with the receiving single-board receiving parameters, the locking power can be set to -30dBm.

END



Sale of OSN3500 SS62COA_Products_Quotation_Sales_Manufacturers_Features_of_Products Product Description_Huawei SDH Transmission Equipment Sales
Supply OSN3500 SS62COA_Troubleshooting_Installation and Testing_Technical Specifications_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板