Question Description
When OSN3500 devices are configured for TPS protection, can N2PQ3 be used as the protection board if the protected board is PL3/PD3? If it can be used, how many bridge boards TSB8 need to be configured at this time ?
Alarm message
None
Processing
1. When OSN3500 devices are configured for TPS protection, when the protected single board is PL3/PD3, you can use N2PQ3 as the protection board.
2, when the protection board and the protected board are both N2PQ3, you need to use two bridge board TSB8 single board; when the protection board is N2PQ3 and the protected board is PL3/PD3, you also need to use two TSB8 single boards, and the two bridge boards TSB8 are required to be in position, or else it is considered that the protection single board is bad, and thus can not act as a single board protection.
Root cause
None
Recommendations & Summary
None