Optix OSN3500 modifies the network element nodeid and then the network element enters the state of security
| 2025-11-21|Back

Problem Description

One day, an operator's maintenance personnel wanted to modify a set of non-gateway network element OSN3500 equipment to become a gateway network element, in accordance with the method of modifying the network element ip modification, but always unsuccessful , and then queried the version of R3 ( 5.21.13.47p01 ), querying its nodeid is 129.9.0.1, and want to modify the gateway network element's ip address is 129.9.11.15, the two ip addresses are in a network segment, so it is not possible to modify the ip address of the gateway. The engineers of the partner were allowed to modify the nodeid of the gateway, but after the modification was completed, the soft reset of the main control board reported that the gateway was in the state of security alarms. The alarm disappeared after the full-volume download of the service to the network element on site.

Alarm information

ne-install

Processing

1, R & D from the returned data can see that in a few days before the modification of the network element nodeid, someone manually deleted the drdb database operation; resulting in no data in the drdb database; so when the main control board soft reset up to report that the network element is in the state of security alarm.

2, OSN3500 equipment database backup mechanism:

Since the OCP data adopts incremental backup, i.e., it will only store the new configuration data to DRDB, and back up the data in DRDB to flash in the network element cycle backup. As the data in FDB0 was also cleared during the clearing operation on 2007-12-26, the network element was automatically reset after modifying the Nodeid8 days after the event, and after resetting up, the network element restored the default configuration, and thus the network element entered the installation state.

3, mdb data is backed up to drdb, and drdb data is periodically backed up to fdb, real-time backup to nvfldb, the process of backing up from mdb to drdb is an incremental backup method.

Root Cause

Database anomaly.

Recommendations and Summary

The configuration must be re-downloaded after manually deleting the database, otherwise it will leave the network element in an an state when the master is reset up.


Sales Optix OSN3500_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH Transmission Equipment Sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板