optix OSN1500 SSN1D12S non-stop up and down problem
| 2025-11-21|Back

Problem Description

OSN1500B, single board configuration (as shown in the figure OSN1500B configure board panel.JPG), when you open the network element control panel, found that 17 # D12S display is not normal. With the command line :cfg-get-board and :cfg-get-phybd query results as attached (1.txt).17 #D12S single board physical board query can not be. The version information before upgrade is attached as (before upgrade EFT8 board.xls).

Alarm information

None

Process

Avoidance Solution .

Adjust the slot configuration of the existing network. If a processing board with interface board (for example, pd1 ) is inserted in slot 8, then a single board with EFT8 is not inserted in slot 13 at the same time; if a single board with EFT8 is inserted in slot 13, then a processing board with interface board (for example, pd1 ) is not inserted in slot 8 at the same time.

If slot 7 inserts a processing board with an interface board (e.g., pd1 ), then slot 12 does not also insert an EFT8 single board; if slot 12 inserts an EFT8 single board, then slot 7 does not also insert a processing board with an interface board (e.g., pd1 ).

2, do not have to move the configuration of the existing network, this problem will not affect the business, and there is no alarm, but when you open the slot installation diagram, you will see that the interface board is lighted and grayed out.

Fundamental solution .

The latest version of R9 will be released in August to solve this problem. After the release of this version, the first line only needs to upgrade the EFT8 single board software to solve this problem. After upgrade version information as attached

(after upgrade EFT8 board.xls)

Root cause

The up and down line of the interface board is that the host software queried the status of its interface board to the processing board at regular intervals, and after locating the software processing there is a problem. The data board EFT8, when receiving the host querying the status of the interface board, reported more than one, more than one is an empty board type, the host processing will be 17 slots position offline, the 8 board will be placed on the line of 17, so that the cycle of processing led to the 17 slots can not be on the line.

Recommendation and Summary

This issue will not affect the business, and there is no alarm report, so it can be said that it is not perceptible to customers and basically does not affect the use. If customers are not concerned about this issue, they can ignore it.


Sell OSN1500B Optical Transmitter_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply OSN1500B Optical Transmitter_Troubleshooting_Installation and Testing_Technical Index_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板