BUSERR alarm reported on OSN2000 cross boards
| 2025-11-21|Back

Phenomenon Description

A bureau OSN2000 spare cross board reports BUSERR alarm, the alarm parameter is 01 00 0C FF FF , the cross board has been replaced, the alarm still does not disappear.

Cause analysis

The BUS_ERR alarm indicates that the service bus sent from the service board to the cross-board is faulty or the service bus sent from the cross-board to the service board is faulty.

Procedure

Since the crossover board has been ruled out, the possibility of business board failure is higher. According to the description in the product manual, the third parameter of BUSERR, 0C, indicates the bus number, but the relationship of the bus number corresponding to the board position has not been found in the available information.

The corresponding relationship between bus number and board position of OSN2000 is shown in the following table

The third parameter of this problem is 0C, decimal 12, which corresponds to slot 6. The problem is solved by replacing the 6-slot single board.

Recommendation Summary

No


Sell Huawei OSN2000 Optical Transmitter_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH Transmission Equipment Sales
Supply Huawei OSN2000 Optical Transmitter_Troubleshooting_Installation and Testing_Technical Specifications_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板