Problem Description
On a customer 's OSN7500 device, when setting the operating mode of the EMS4 single-board optical interface board ports to 100M full-duplex, it prompts the wrong operating mode, and only the default " auto " mode (self-negotiation) can be used. Product version: V2R11C00SPC200.
Alarm message
None
Processing
Temporary measures: Avoid setting the working modes of (N1/N2/N4/N5) EFS0, (N1/N2/N3) EFS4, N1EMS2, N1EMS4, and the working modes of the optical interface board ports on the single board, and make sure that the working modes of the optical interface board ports on both boards are in " auto " mode.
Solution: Upgrade the product version to V2R11C00SPC300 to solve the problem completely.
Root cause
When the product version is V2R11C00SPC200, the corresponding platform version is USPV1R5C00B181. When setting the working mode of the single-board ports, the first thing to do is to query the configuration file of the single-board to see if the mode is supported, and since there is no relevant configuration in the configuration file of the corresponding single-board, it fails to set the working mode of the single-board optical ports, and an error is returned.
Recommendations and Summary
1. The optical interface board ports on the R11C00SPC200(N1/N2/N4/N5) EFS0, (N1/N2/N3) EFS4, N1EMS2, and N1EMS4 single boards are unable to set the working mode, and the working mode is always the default value of " auto ". Because all the ports of the transmission equipment support " auto ", it does not affect the customer's service configuration, but it is not possible to set the specific working mode, which may cause the customer's doubt.
2、This problem only involves the optical interface board, not the electrical interface board, the electrical interface board can be set.