18529092692

Home >> News
News
OSN2500 SSN1ADQ1 crossboard reset when single board binds time slots
| 2025-11-21|Back

Problem description

When a new OSN2500 ADQ1 veneer board is opened for service and binds a time slot, the operation fails; the time slot binding of SDH/ ATM service cannot be completed, and when the SDH/ ATM service binds a time slot and fails, the master cross-talk line integration veneer board CXL will reset.

Warning Message

When binding time slots for SDH/ ATM services, it prompts: the background is busy or the device is carrying out other operations, it cannot respond for the time being, please check and retry, error code: 126979

Processing

1. query errlog:#9-21:szhw [21-ICB large customer MSTP][2009-08-11 18:20:27+08:00]>

:errlog

ResetLog:: total reset times = 10

No.0: 1990-1-1 0:20:41

BOARD=82 TYPE=0xf0000004 SOFTTYPE=2

No.1: 2009-6-25 10:21:55

BOARD=83 TYPE=0xf0000004 SOFTTYPE=2

No.2: 2009-6-25 10:53:21

BOARD=83 TYPE=0x10 SOFTTYPE=2

No.3: 2009-6-25 12:0:36

BOARD=83 TYPE=0xf0000004 SOFTTYPE=2

No.4: 2009-6-25 13:37:51

BOARD=83 TYPE=0xf0000004 SOFTTYPE=2

No.5: 2009-7-6 17:16:52

BOARD=83 TYPE=0xf0000004 SOFTTYPE=2

No.6: 2009-7-31 15:20:45

BOARD=83 TYPE=0x10 SOFTTYPE=2

No.7: 2009-7-31 15:51:4

BOARD=83 TYPE=0x10 SOFTTYPE=2

No.8: 2009-8-11 8:6:17

BOARD=83 TYPE=0xf0000010 SOFTTYPE=2

No.9: 2009-8-11 10:2:18

BOARD=83 TYPE=0xf0000010 SOFTTYPE=2

# 2009-6-25 10:52:29

fatal task errorcode=f0000010, Line 434 in ecc_hbu.cpp

# 2009-6-25 10:52:29

fatal task errorcode=f0000010, Line 1362 in reset:TECCHSC

# 2009-6-25 13:36:26

fatal task errorcode=f0000013, Line 1354 in reset:083TBDMcm

# 2009-6-25 13:49:47

fatal task errorcode=f0000013, Line 1354 in reset:083TBDMcm

# 2009-7-31 15:19:53

fatal task errorcode=f0000010, Line 434 in ecc_hbu.cpp

# 2009-7-31 15:19:53

fatal task errorcode=f0000010, Line 1362 in reset:TECCHSC

# 2009-8-11 8:5:8

fatal task errorcode=2015, Line 235 in Atm_VcTrunkDb.c

# 2009-8-11 8:5:8

fatal task errorcode=f0000010, Line 1406 in reset:tAtm

# 2009-8-11 10:1:9

fatal task errorcode=2015, Line 235 in Atm_VcTrunkDb.c

# 2009-8-11 10:1:9

fatal task errorcode=f0000010, Line 1406 in reset:tAtm

Confirmed as a database issue.

2. Processing method:

a. Use the following command to delete all database information

:dbms-delete-database:all,drdb,slave

:dbms-delete-database:all,fdb0,slave

:dbms-delete-database:all,fdb1,slave

:dbms-delete-database:all,drdb,master

:dbms-delete-database:all,fdb0,master

:dbms-delete-database:all,fdb1,master

b. Hard reset backup master

Hard reset the master

c. Use network management to re-download all configurations to the network element

d. Delete all SDH/" target="_blank" >ATM logic boards and re-add them

Root Cause

The database of the ADQ1 board is backed up every 30 minutes, if there is a master board or ADQ1 board reset within 30 minutes of the ADQ1 board configuration data, it will lead to database abnormality; and when the time slot of VCTRUNK is bound, the ADQ1 board needs to update the data; at this time, the database abnormality will lead to the failure of the operation;

Recommendations and Summary

None

END


Supply OSN2500 SSN1ADQ1_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH Transmission Equipment Sales
Supply OSN2500 SSN1ADQ1_Troubleshooting_Installation and Testing_Technical Specifications_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板