Problem description
When a new OSN2500 ADQ1 veneer board is opened for service and binds a time slot, the operation fails; the time slot binding of SDH/ ATM service cannot be completed, and when the SDH/ ATM service binds a time slot and fails, the master cross-talk line integration veneer board CXL will reset.
Warning Message
When binding time slots for SDH/ ATM services, it prompts: the background is busy or the device is carrying out other operations, it cannot respond for the time being, please check and retry, error code: 126979
Processing
1. query errlog:#9-21:szhw [21-ICB large customer MSTP][2009-08-11 18:20:27+08:00]>
:errlog
ResetLog:: total reset times = 10
No.0: 1990-1-1 0:20:41
BOARD=82 TYPE=0xf0000004 SOFTTYPE=2
No.1: 2009-6-25 10:21:55
BOARD=83 TYPE=0xf0000004 SOFTTYPE=2
No.2: 2009-6-25 10:53:21
BOARD=83 TYPE=0x10 SOFTTYPE=2
No.3: 2009-6-25 12:0:36
BOARD=83 TYPE=0xf0000004 SOFTTYPE=2
No.4: 2009-6-25 13:37:51
BOARD=83 TYPE=0xf0000004 SOFTTYPE=2
No.5: 2009-7-6 17:16:52
BOARD=83 TYPE=0xf0000004 SOFTTYPE=2
No.6: 2009-7-31 15:20:45
BOARD=83 TYPE=0x10 SOFTTYPE=2
No.7: 2009-7-31 15:51:4
BOARD=83 TYPE=0x10 SOFTTYPE=2
No.8: 2009-8-11 8:6:17
BOARD=83 TYPE=0xf0000010 SOFTTYPE=2
No.9: 2009-8-11 10:2:18
BOARD=83 TYPE=0xf0000010 SOFTTYPE=2
# 2009-6-25 10:52:29
fatal task errorcode=f0000010, Line 434 in ecc_hbu.cpp
# 2009-6-25 10:52:29
fatal task errorcode=f0000010, Line 1362 in reset:TECCHSC
# 2009-6-25 13:36:26
fatal task errorcode=f0000013, Line 1354 in reset:083TBDMcm
# 2009-6-25 13:49:47
fatal task errorcode=f0000013, Line 1354 in reset:083TBDMcm
# 2009-7-31 15:19:53
fatal task errorcode=f0000010, Line 434 in ecc_hbu.cpp
# 2009-7-31 15:19:53
fatal task errorcode=f0000010, Line 1362 in reset:TECCHSC
# 2009-8-11 8:5:8
fatal task errorcode=2015, Line 235 in Atm_VcTrunkDb.c
# 2009-8-11 8:5:8
fatal task errorcode=f0000010, Line 1406 in reset:tAtm
# 2009-8-11 10:1:9
fatal task errorcode=2015, Line 235 in Atm_VcTrunkDb.c
# 2009-8-11 10:1:9
fatal task errorcode=f0000010, Line 1406 in reset:tAtm
Confirmed as a database issue.
2. Processing method:
a. Use the following command to delete all database information
:dbms-delete-database:all,drdb,slave
:dbms-delete-database:all,fdb0,slave
:dbms-delete-database:all,fdb1,slave
:dbms-delete-database:all,drdb,master
:dbms-delete-database:all,fdb0,master
:dbms-delete-database:all,fdb1,master
b. Hard reset backup master
Hard reset the master
c. Use network management to re-download all configurations to the network element
d. Delete all SDH/" target="_blank" >ATM logic boards and re-add them
Root Cause
The database of the ADQ1 board is backed up every 30 minutes, if there is a master board or ADQ1 board reset within 30 minutes of the ADQ1 board configuration data, it will lead to database abnormality; and when the time slot of VCTRUNK is bound, the ADQ1 board needs to update the data; at this time, the database abnormality will lead to the failure of the operation;
Recommendations and Summary
None
END


Chinese