One day, the customer feedback in the U2000 network management on the pre-configuration OSN 3500 to add a SLO1 single board, add the port prompted the single board does not support dynamic ports, error code: 1090593570 , as shown in the figure:

f48968b1f7434ea0b851032a8f202ebd

Solution

After querying the network management fromT2000V2R2开始新增OSNdynamic port management function, OSN1500/2500/3500/7500设备5.*.13.10 later versions to support theDynamic ports, so to add dynamic ports you need to change the preconfigured network element version to a version greater than 5.*.13.105.*.13.10,而查看网管预配置OSN 3500版本默认为5.21.12.10版本过低。 After modifying it, it can be configured normally.