In the use of Huawei Metro1000 equipment in the process of frequent testing of spare parts, spare parts can easily be damaged resulting in equipment failure, regular inspection of equipment related spare parts to ensure that the normal operation of the spare parts, there are any problems in a timely manner, for the inability to deal with the case of the operation under the guidance of technical personnel.
Through the regular maintenance of Metro1000 spare parts, to ensure that spare parts can be replaced at any time online veneer, improve maintenance efficiency.
Inspection Criteria
The BIOS version, software version and logic version of the spare parts should be the same as the version of the same kind of single board running on the network.
Reference Information
The maintenance principles of spare parts are as follows:
Principle of spare parts inspection
Regularly check the spare parts version and quality, and test the spare parts.
The software version, PCB version and FPGA version of the spares should be consistent with the version of the single board running on the network.
When the network is upgraded, the corresponding Metro1000 spare parts should be provided in time, and the version of the existing spare parts should be upgraded synchronously.
Principle of spare parts storage
Spare parts must be stored in accordance with the requirements and kept by specialized personnel to ensure the exclusive use of spare parts.
Spare parts should be stored in anti-static bags, not rubbing each other, and placed in special anti-static cabinets, not piled up with other sundries.
Wear anti-static gloves when accessing spare parts.
Spare parts in and out of the warehouse information records must be updated in a timely manner, so as to replenish the appropriate spare parts in a timely manner.
Operation Steps
1. Use the following methods to check and record the BIOS version, main control software version, single board software version, logic version and PCB version of the spare parts with T2000. It should be consistent with the version of the same kind of single board running in the network.
a. Log in to the T2000 client and select "Report > Veneer Information Report" in the main menu.
b. Click the left navigation tree icon to refresh the navigation tree, after refreshing the navigation tree, select the network elements and veneers to be queried, click.
c. Click "Query", the operation result dialog box pops up to indicate the success of the operation.
d. Click "Close", the interface will display the status and version information of each single board of the network element.
e. Record the BIOS version, software version, PCB version and Logic version of the network element.
2. Conduct quality tests on Metro1000 spare parts to ensure that the spare parts are available.
When checking the Metro1000 spare parts, pay attention to the relevant prerequisites and the condition of the equipment, refer to different materials to understand the relevant information, and operate in conjunction with the actual situation during the operation.


Chinese