OSN3500 fiber optic transmission equipment EMS2 single board supports Layer 2 switching, link aggregation, multicast and other functions and features. Interface type support 1000BASE-SX/LX/ZX/VX Ethernet optical interface, support for self-negotiation, using pluggable SFP optical interface, multi-mode fiber transmission distance up to 550m, single-mode fiber up to 10km, support for 1000BASE-T Ethernet electrical interface, support for self-negotiation, can be self-negotiated for 10M, 100M or 1000M rate. Adopting pluggable SFP electrical interface, the transmission distance can reach up to 100m. with the outlet board with the ETF8 to realize 16-channel FE electrical signal access. Realize 16-channel FE optical signal access with EFF8. 8-channel FE electrical signal and 8-channel FE optical signal access with ETF8 and EFF8. Support EVPL service with shared PORT. Support EVPL service with shared VCTRUNK. Supports data isolation based on VB+VLAN method.
Problem Description
The T2000V2R7C03SPC003 network administrator creates a VB of bridge type 802.1Q on the N1EMS2 board of the OSN3500 device, and prompts "This command is not supported, error code 38737" when it connects ports, and the ports cannot be connected.
Host version: 5.21.19.22
OSN3500 Fiber Optic Transmission Unit N1EMS2
Processing
1:After uploading data, reconfiguration failure remains;
2: Change the bridge type and the problem still exists. Check the description of the single board which also supports 802.1Q;
3: Check the version of the supporting table host with the single board is also supporting; network management requirements for the R7C02, the site R7C03 should be no problem to use the R8 network management configuration failure remains;
4: Get the relevant data to the R & D analysis, confirmed that the R7C03/R8 network management support the command to set the bridge type, but 5.21.19.22 hosts are not supported. There is a problem with the downward compatibility of the network management;
6: Use R7C02 network management configuration temporary solution, followed by R & D to give a complete solution.
VB can not hook up theroot cause of theport
1: Inconsistency between network management and network element data;
2: 802.1Q type bridge is not supported, only 802.1d or mixed mode;
3: The host does not match with the single board;
4: Problems in the cooperation between the network management and the host;
The related technical information in this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.