| Alarms | Name | Alarm Level | Starting Version |
|---|---|---|---|
| LOL | Receiver subchannel not aligned | Emergency |
V100R001C01 |
| OCH_FDI | OCh layer forward defect indication | Tip |
V100R001C01 |
| OCH_FDI_O | OCh layer monitor signal forward defect indication (overhead) | Prompt |
V100R001C01 |
| OCH_FDI_P | OCh layer forward defect indication (net load) | Prompt |
V100R001C01 |
| OCH_LOS_P | OCh layer signal loss (net load) | Urgent |
V100R001C01 |
| OCH_OCI | OCh layer open connection indication | Secondary |
V100R001C01 |
| OCH_SSF | OCh layer service signal failure | Tip |
V100R001C01 |
| OCH_SSF_O | OCh layer service signal failure (overhead) | Prompt |
V100R001C01 |
| OCH_SSF_P | OCh layer service signal failure (net load) | Prompt |
V100R001C01 |
| OMS_BDI | OMS layer backward defect indication alert | Alert |
V100R001C01 |
| OMS_BDI_O | OMS layer monitoring signal backward defect indication (overhead) alarm | Alert |
V100R001C01 |
| OMS_BDI_P | OMS layer backward defect indication (net load) alarm | Alert |
V100R001C01 |
| OMS_FDI | OMS layer forward defect indication alarm | Alert |
V100R001C01 |
| OMS_FDI_O | OMS layer monitoring signal forward defect indication (overhead) alarm | Alert |
V100R001C01 |
| OMS_FDI_P | OMS layer forward defect indication (net load) alarm | Alert |
V100R001C01 |
| OMS_LOS_P | OMS layer service signal (net load) loss alarm | Urgent |
V100R001C01 |
| OMS_PMI | OMS layer net load loss indication alarm | Emergency |
V100R001C20 |
| OMS_SSF | OMS layer service signal failure alarm | Alert |
V100R001C01 |
| OMS_SSF_O | OMS layer service signal failure (overhead) alarm | Alert |
V100R001C01 |
| OMS_SSF_P | OMS layer service signal failure (net load) alarm | Alert |
V100R001C01 |
| OOS_LOST | Loss of overhead information used for optical layer monitoring and processing alarm | Secondary |
V100R001C01 |
| OTS_BDI | OTS layer backward defect indication alarm | Alert |
V100R001C01 |
| OTS_BDI_O | OTS layer monitoring signal (overhead) backward defect indication alarm | Alert |
V100R001C01 |
| OTS_BDI_P | OTS layer backward defect indication (net load) alarm | Alert |
V100R001C01 |
| OTS_LOS | OTS Layer Signal Loss Alarm | Urgent |
V100R001C01 |
| OTS_LOS_O | OTS layer monitoring signal (overhead) loss alarm | Important |
V100R001C01 |
| OTS_LOS_P | OTS layer service (net load) signal loss alarm | Urgent |
V100R001C01 |
| OTS_PMI | OTS layer net load loss indication alarm | Emergency |
V100R001C20 |
| OTS_TIM | OTS layer path trace identifier mismatch alarm | Secondary |
V100R001C01 |
The related technical information and SDH equipment troubleshooting procedures in this chapter are collected and organized by Shenzhen Optical Transmission Network Technology Co. Our company specializes in the sales of Huawei SDH optical transmission equipment,SDH transmission equipment.