N402 veneers with different optical line code types cannot be docked, for example, QPSK, QPSK wDCM, QPSK wDCM-Enhanced are different code types, T51 uses QPSK, T61 uses QPSK wDCM, and they cannot be docked;
T6x supports AFEC level configurable, docking is supported only when the AFEC level at both ends is configured to be the same.The transmission distance of T6x is compared as follows: T61>T62>T65, and the actual transmission distance is based on the shorter one after docking of different veneers;
Single boards with different error correction codes cannot be docked. HFEC, SDFEC, SDFEC2, etc. are different error correction codes.
Single-board metrics include optical interface metrics, single-board size, weight, and power consumption. Single-board module description
| Single Board Name | Module Name | Supported Service Type | Module Type | Module Use Location |
|---|---|---|---|---|
| TNU1N402T11 | C-band-tunable wavelength-ePDM-QPSK (SDFEC, NRZ)-PIN indicator | OTU4 | Fixed | Wavelength Division Side |
|
TNU2N402T51 TNU3N402T51 |
C-band-tunable wavelength-ePDM-QPSK (SDFEC2)-PIN indicator | OTU4 | Fixed | Wavelength Division Side |
|
TNU2N402T61 TNU3N402T61 |
C-band-tunable wavelength-ePDM-QPSK (SDFEC2, wDCM)-PIN indicator | OTU4 | Fixed | Wavelength Division Side |
|
TNU2N402T65 TNU3N402T65 |
C-band-tunable wavelength-ePDM-QPSK (SDFEC2, wDCM-Metro)-PIN indicator | OTU4 | Fixed | Wavelength Division Side |
| TNV2N402T01 | C-band-tunable wavelength-ePDM-QPSK (HFEC)-PIN indicator | OTU4 | Fixed | Wavelength Division Side |
| TNV3N402T41 | C-band-tunable wavelength-ePDM-QPSK (HFEC PLUS)-PIN indicator | OTU4 | Fixed | Wavelength Division Side |
| TNV1N402C01 | CFP-100G(4x25G/28G,Dualrate)-1295nm~1310nm(LR4)-SMF-10km-SP Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G(4x25G/28G,Dualrate)-1295nm~1310nm(LR4)-SMF-10km-SP Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)-(DWDM,Tunable, T5U)-SMF Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable, T5G)-SMF Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable, T65)-SMF Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable, T41)-SMF Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable, T62)-SMF Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable, TxA)-SMF Indicator Description:
|
OTU4 | Pluggable | Wavelength Division Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable, T51)-SMF Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable, T61)-SMF Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable,High Power, T65)-SMF Indicator | OTU4 | Pluggable | WDM Side |
| TNU5N402 | CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable,High Power, T69)-SMF Indicator | OTU4 | Pluggable | Wavelength Division Side |
|
Description:
T5x (SDFEC2, QPSK) can only be used in pure coherent networks; T6x (SDFEC2, QPSK, wDCM) can be used in 10G/40G non-coherent mixed transmission networks, and can also be used in pure coherent networks (but its transmission distance is shorter than that of T5x, and it is not recommended to use). |
||||
CFP-100G-(1529.17nm to 1567.1nm)(DWDM,Tunable, T5G)-SMF Optical Module cannot be used with MSC0816 single board.
CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable,High Power, T65)-SMF and CFP-100G-(1529.17nm~1567.1nm)(DWDM,Tunable,High Power, T69)-SMF Optical Modules are only available for the M24 subrack on the TNU5N402 single board.
The related technical information and SDH equipment troubleshooting procedures in this chapter are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), and are reproduced with permission! Our company specializes in Huawei SDH optical transmission equipment,SDH transmission equipment sales.


Chinese