Description of the problem
Huawei OSN3500 device MSTP SXCSA cross board upgrade operation
Solution
MSTP equipment cross board upgrade operation:
1. Delete the spare crossover logical board on the network management, and after replacing the new crossover board, add the logical board on the network management.
2. Query the current alarm of the network element, and when the HSC_UNAVAIL alarm disappears, then carry out the master and backup inversion.
3. Delete the primary crossover logical board on the network management, and add the logical board on the network management after replacing the new crossover board.
4. Query the current alarm of the network element, when the HSC_UNAVAIL alarm disappears, the replacement of the primary crossover is completed.
5. Verify that the primary backup and primary cross-replacement is normal.
There is a 50MS flash-off for the service in the crossboard master-standby switchover, and it is recommended to apply for a safe time to operate.
The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Co.( www.opticaltrans.com), please retain the reproduction! Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.


Chinese
English





