Domain |
Value field |
Description |
|---|---|---|
|
Port |
- - - - Display the corresponding SDH interface. |
Displays the corresponding SDH interface. |
|
Optical Port Name |
- |
Displays or sets the optical port name. |
|
Laser Switch |
On, Off Default: on |
Displays or sets the interface laser switch status. Only the SDH optical interface board supports this parameter. Normally, the setting is "On". |
|
Optical (Electrical) Interface Loopback |
No Loopback, Inner Loopback, Outer Loopback Default: No loopback |
Displays or sets the loopback status of the SDH interface.
This function is generally used for fault localization of each SDH interface. "Optical (electrical) port loopback" is a diagnostic function, and its use will affect the service of the relevant port, so please use it with caution. In general, the setting is "No Loopback". |
|
VC4 Channel |
-VC4 Channel |
Displays the corresponding VC4 channel. |
|
VC4 Loopback |
No loopback, inner loopback, outer loopback Default: No loopback |
Displays or sets the loopback status of the line unit's VC4 channel.
This function is generally used for fault localization of each VC4 channel. "VC4 loopback" is a diagnostic function, and its use will affect the service of the relevant port, so please use it with caution. Under normal circumstances, the setting is "No Loopback". |
|
VC3 Channel |
-Displays the corresponding VC3 channel. |
Displays the corresponding VC3 channel. |
|
VC3 Loopback |
No loopback, inner loopback, outer loopback Default: No loopback |
Displays or sets the loopback status of the VC3 channel of the line unit.
This function is generally used for fault localization of each VC3 channel. "VC3 loopback" is a diagnostic function, and its use will affect the service of the relevant port, so please use it with caution. Under normal circumstances, the setting is "No Loopback". Description:
This board does not support VC3 inner loopback. |
|
VC12 Channel |
- |
Displays the corresponding VC12 channel. |
|
VC12 Loopback |
No loopback, inner loopback, outer loopback Default: No loopback |
Displays or sets the loopback status of the VC12 channels of the line unit.
This function is generally used to locate faults on each VC12 channel. "VC12 loopback" is a diagnostic function, and its use will affect the service of the relevant port, so please use it with caution. Under normal circumstances, the setting is "No Loopback". Description:
This board does not support VC12 internal loopback. |
|
Field of interest |
Value field |
Description |
|---|---|---|
|
Optical Interface |
- - - - - Display the corresponding optical interface. |
Displays the corresponding optical interface. |
|
Automatic shutdown |
Prohibit, Allow Default: Prohibit |
Displays or sets the "Auto Off" status of the laser. Laser auto shutdown is a function to shut down the laser automatically when the optical interface does not carry service, fiber failure, or loss of received optical signal. When "Allow" is set, "On Time (ms)", "Off Time (ms)" and "Long On Test Time (ms)" can be set. ". |
|
On Time (ms) |
1000~3000 in steps of 10. |
Display or set the time to test whether the fiber is normal or not after turning off the laser, if it is an automatic turning on of the laser. |
|
Off Time (ms) |
2000~300000, step 10. |
Display or set the time when the laser is turned off automatically (this parameter can be set only when the laser auto off function is turned on). |
|
Long open test time (ms) |
2000~300000, step 10. |
Display or set the time to test whether the fiber is normal or not after turning off the laser, if the laser is turned on manually. |
The technical information related to this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Co.(www.opticaltrans.com), please retain! Our company specializes in Huawei SDH optical transmission equipment,SDH transmission equipment sales.