Description of the problem
The standby master of Huawei OSN1500 equipment fails, and after replacement, the network management right-click queries the standby master version and the main master version, but the two versions are inconsistent when queried with the sftm-get-nesoftver:bid command; the two versions queried by the T2000 network management are consistent with the main master version.
Processing
T2000 network management on the right to query the main standby master version for the network elements are issued the command sys-get-nesoftver; so the display is the version of the primary master
Solution
So after replacing the backup master, you should use the command sys-get-nesoftver to query the master version, and then query the backup status.


Chinese
English