Description of the problem
To meet the functional requirements of the current network elements, the current network needs to upgrade the device version from 5.21.12.43 to 5.21.18.50. In accordance with the OptiX_NG-SDH product upgrade guidebook (TOOLKIT_R4), the N1GSCC master board of Huawei OSN3500 device is upgraded to the basic BIOS version using the ToolkitV100R004C01B01q tool. When upgrading the basic BIOS, the Toolkit tool was able to activate the basic BIOS version successfully, but the update of the basic BIOS version was unsuccessful, suggesting that "the software version has not been updated", and the site was checked through the command line, and the software version was still the original upgraded version, which had indeed not been updated;
Huawei OSN3500 Device Alarm Messages
The base BIOS update was unsuccessful, and the device had no abnormal alarms; the Toolkit tool prompted "Software version not updated";
Processing
1、Check the upgrade steps, consistent with the instructions in the upgrade guide, to rule out operational problems;
2、Suspect Toolkit tool problems, the scene using navigator software for basic BIOS upgrade loading, still can not operate successfully;
3, upgrade the software package problem, the scene by re-applying for new software to reload, the basic BIOS software still can not be updated;
4、After the company finally analyzed and positioned, the scene from the main master OFS2 copy of the basic BIOS to the main master OFS1 file system, that is:
:sftm-copy-file:bid,"/ofs2/hwx/basebios.hwx",bid,"/ofs1/hwx/basebios.hwx";
5. # Activate the base BIOS, bid is the main control board bit
:cfg-active-basebios:bid
6, and then finally use the tool to activate (i.e.: reset) or manual soft reset the motherboard. However, after this operation, the basebios.hwx file will be left in the motherboard, if the motherboard space is insufficient, you can manually delete the file after the activation is completed.
Root Cause
1. Wrong upgrade procedure;
2, Toolkit tool problem;
3, software package problems;
4, there are problems with the method of upgrading the base BIOS in this version;
Recommendations and Summary
For Huawei OSN3500 devices with GSCC single board target version R8C02 and later versions, the base BIOS needs to be updated (e.g., the original host version 5.21.12.43 is updated to 5.21.18.50), and there are differences in the steps for upgrading with other previous versions. When Toolkit loads the BIOS file, the BIOS file is loaded into the main control board file system OFS2, and when Toolkit activates the BIOS, the default is to activate the file in OFS1, and at this time there is no loaded BIOS file in OFS1, which results in Toolkit reporting the following "Software version not updated" prompt, please pay attention to this scenario when loading and updating the base BIOS version; R&D has been asked to change the toolkit R4 upgrade guide, please pay attention to the upgrade guide when upgrading.
The technical information related to this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), please retain the reproduction! Our company specializes in the sales of Huawei SDH optical transmission equipment, SDH transmission equipment.


Chinese