Description of the problem
Huawei OSN3500 device network element version 5.21.18.50P01 has been configured with high power TN51PDU, but the query subrack power threshold is still 1100 W. Need to confirm whether it can be upgraded to 2300 W mode, how to do it?
Processing
1. Confirm that the backplane version type is VER.
:cfg-get-bdinfo:17
Description=OptiX OSN3500,SSN3GSCC02,System Control and Communication Board,1x1 Assembled Board
Manufactured=2010-11-05
VendorName=Huawei
IssueNumber=00
CLEICode=
BOM=
AFB PCBVER = E
2. The site confirms that the DC distribution box is a TN51PDU and that the subrack PIUB has been connected to the 63A power output.
3. After confirming the completion, issue the command to switch to high power consumption mode.
:cfg-set-nepowerth:0xff01
4. After the switching is completed, you can query the current supported power consumption threshold via :cfg-get-powerinfo.
Suggestions and Summary
:cfg-set-nepowerth: //Set command: 0xff00---normal power consumption mode; 0xff01---large power consumption mode
The power consumption supported by different types of backplanes in the two modes is (W):
(Backplane type/OSN3500 normal power consumption mode/large power consumption mode)
AFB backplanes are VerA/720/960,
Ver=B/720/960.
Ver=C/1100/1100.
Ver=D/1100/1100.
Ver=E/1100W/2300W
Large power consumption characteristics can be referred to the information: SC0000568122