Huawei OSN3500 device reported IP address error when creating tunnel
| 2025-11-21|Back

Description of the problem

A customer needs to create an E-LSP service on N1PEG8, and the network administrator reported an IP address error when creating the tunnel, error code:42161 (see attachment). The customer double-checked the IP and did not find any problem with the IP settings.

Host version: V200R011C00SPC200


Alarm information

42161: The IP address is incorrect


Processing

Recovery measures: Set the GCP NODEID in the network element once again according to the GCP NODEID queried from the database. During the setup process, the master and backup master control boards will be reset at the same time, and the packet service may be interrupted for about 10 minutes during the process. After the master reset is completed, the service is automatically restored, the network element operates normally, and a new tunnel can be created (the purpose of which is to reset the GCP NODEID in the database to the system parameter area).

The specific steps for resetting are as follows:

1. query the GCP NODEID in the database. for example:

:cfg-get-gcpnodeidGCP NODEID : 77.77.77.77

2、Reset the GCP NODEID once: :cfg-set-gcpnodeid:77.77.77.77

3、Wait for the master reset, and re-create the tunnel after reset up.

Root solution: In V2R11C00SPC300 and subsequent versions, this problem does not occur.


Root Cause

After R&D, the root cause is confirmed as follows: During the smooth upgrade from Huawei OSN3500 N4GSCC to N6GSCC, the database download process only downloads the database of the configuration plane, but not the database of the system parameter area (the GCP NODEID of the checksum in the PTN is saved in the system parameter area).

After the N4 smooth upgrade to N6, the previous GCP NODEID (i.e. LSR ID) is not synchronized to the new master, and the system parameter area of the new master is an invalid value by default. Therefore, after the master upgrade is completed, it will cause the new tunnel to fail and return IP incorrect.


Suggestion and Summary

After this problem occurs in the current network, it can only be solved with recovery measures.



This chapter of related technical information and SDH equipment troubleshooting process is collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), reproduced please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板