18529092692

Home >> News
News
OSN3500 N4GSCC upgrade to N6GSCC causes network elements to fail to create MPLS tunnel
| 2025-11-21|Back

Description of the problem

A frontline engineer fails to create a new MPLS tunnel on an OSN3500 network element, returning error code 42161 (IP address error)

Host version: V2R11C00SPC100


Alarm message

No


Processing

Reset the GCP NODEID once on the network element according to the GCP NODEID queried from the database

The steps to reset the GCP NODEID are as follows:

1) Query the database for the GCP NODEID, for example:

:cfg-get-gcpnodeid

GCP NODEID : 77.77.77.77

2) Reset the GCP NODEID once:

:cfg-set-gcpnodeid:77.77.77.77

3) Wait for the master to reset, and after it resets up, check if the new tunnel is successful.


Root Cause

A software defect causes that after smoothing N4GSCC to N6GSCC or N6GSCC to N4GSCC, the previous GCP NODEID is not synchronized to the new master, and the system parameter area of the new master is an invalid value by default. Therefore, after the master smoothing upgrade is completed, it will cause the new tunnel to fail and return IP incorrect.


Suggestion and Summary

According to the GCP NODEID queried from the database, reset it once on the network element

The steps to reset the GCP NODEID are as follows:

1) Query the database for the GCP NODEID, for example:

:cfg-get-gcpnodeid

GCP NODEID : 77.77.77.77

2) Reset the GCP NODEID once:

:cfg-set-gcpnodeid:77.77.77.77

3) Wait for the master to reset, and after it resets up, check if the new tunnel is successful.

Using V2R11C00SPC300 and later V2R11 versions for N6 and N4 interchanging can solve this problem.



The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Co. Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板