Configure the OSN3500 device N3EGS2 board with the service prompt error code 38735
| 2025-11-21|Back

Description of the problem

Webmaster version: U2000V1R2C01 Webmaster ;)

Device Type: OSN3500;.

Host version: 5.21.31.15;.

Crossover board: N2PXCSA.

Failure phenomenon: single station method to configure two-way cross service: 3-N3EGS2-1-VC4-12-VC12:1 <--->14-N1SLQ4-2 -VC4-1-VC12:4; Configuration service is not successful, prompting "Matrix arithmetic submodule calibration service connection failed", error code: "38735";

Configuration of the service was unsuccessful;


Alarm message

No abnormal alarms on the network management;


Processing

1, according to the operation fault prompt information, "matrix arithmetic submodule calibration service connection failure", belongs to the business configuration calibration failure problem, should be a bus problem; or single board problems;

2. Check the data and find that there are services running normally on VC4s from 1 to 8 of the N3EGS2 board. Configure the service on the 8th VC4 of N3EGS2 to the service on the optical board, and it can be configured normally, which rules out the host abnormality, and the problem of the cross-board.

3, reconfigure the N3EGS4 board on the 9th to 16th VC4 services to other optical boards, verification, found that 9 to 16 VC4 on the VC3, VC12 services can not be configured normally. It is very regular that the services on the 9th to 16th VC4 cannot be configured, suspecting a bus bandwidth problem;

4, N3EGS2 single board supports 2.5G bandwidth, N2PXCSA for 200G high-order crossover, N3EGS2 inserted in the 3-board position, support for 2.5G bandwidth; and in the Ethernet internal port binding, you can bind 9 ~ 16 VC4 services; exclude the problem of unsupported bandwidth;

5. Collect data on the network elements and find that there are shielded alarms on the equipment. The alarms of the N3EGS2 single board at board position 3 are: T_LOSEX alarm;

After the company's R & D to confirm: OSN3500 equipment, for the 5.21.31.15 host version, when the cross-board type for the N2PXCSA, the master default configuration of the 1,2,3,4,15,16 slots backplane bus rate of 622M; resulting in support for 2.5G bandwidth in conjunction with the Ethernet veneer, resulting in insufficient bandwidth of the six slots, EOS veneer reported T_LOSEX alarm. LOSEX alarm. This results in data anomalies when 9 to 16 VC4s are configured in 3 board positions;

6, host upgraded to V2R11C00SPC300 and after the V2R11 version can solve the problem, the field will be upgraded to the host after 5.21.31.38, the business configuration is successful;


Root cause

1, N3EGS2 single board problem;

2. Insufficient cross capacity;

3, other problems;


Recommendations and Summary

When configuring the services of the OSN3500 N3EGS2 board, please pay attention to the N2PXCSA board, host configuration.



The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Co. Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板