Description of the problem
After OSN3500 multiplexed segment inversion, the service is interrupted and AU_AIS alarm is reported.
Processing
1. Issue the following alarm to the line veneer of the inverted network element and the pass-through network element:alm-get-insertalm
2. The channel through which the interrupted service passes has AU_AIS alarms inserted.
Root cause
When the cross veneer canceled the multiplexed segment suppression command to the line veneer, some of the commands were lost due to too many commands issued at one point in time. The line veneer suppresses the residue.
Solution.
De-activate the activation operation for the interrupted service, or restart the reuse segment protocol for the located network element.
Recommendations and Summary
It is recommended that a reversal test be performed for each cycle of the multiplexed segment.
The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Co.( www.opticaltrans.com), please retain the reproduction! Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.