Description of the problem
The following alarm occurs on an OSN1500B network element without operation, and the cause of the alarm needs to be found out.
235439 10 BD_STATUS MJ end 2013-03-11 02:30:59 2013-03-11 02:31:42 0xff 0xff 0xff 0xff 0xff 0xff 0xff
235440 18 BD_STATUS MJ end 2013-03-11 02:31:13 2013-03-11 02:32:05 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff
235441 19 BD_STATUS MJ end 2013-03-11 02:31:13 2013-03-11 02:32:05 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff
The single board information is as follows:
:cfg-get-board.
INSTALLED-BOARD
BID BD-TYPE ACTIVE-STATE
3 ssr1sld4 active
4 ssq1sl4 active
5 ssq1sl4 active
6 ssr2pd1 active
7 ssr2pd1 active
8 ssr2pd1 active
10 aux active
11 ssn1slq1 active
12 ssn1slq1 active
13 ssr1sld4 active
15 ssn1d12s active
17 ssn1d12s active
18 piu active
19 piu active
20 ssr1fan active
80 ssq2ecxl active
81 ssq2ecxl active
82 gscc active
83 gscc active
Total records :19
BD_STATUS
Processing
Due to the limited subrack space of OSN1500 network elements (including 1500A and 1500B), the in-position line of the PIU board is sent to the master through the AUX, so that the AUX soft reset will cause the PIU to report the BD_STATUS alarm at the same time. This is a hardware feature of the OSN1500.
Root Cause
The OSN1500 network element PIU's presence line is sent to the master through the AUX, so the AUX soft reset will cause the PIU to report the BD_STATUS alarm at the same time.
Solution
1, the first suspected bd_status alarm known problem: in-position line jitter. According to the relevant case troubleshooting ruled out.
2, because the PIU is reported at the same time, disappear at the same time, it is impossible to be two PIU at the same time hardware problems reported not in position.
3, observe 10 # board AUX alarm time and PIU alarm time in the report time and end time seems to have a little connection.
4, check the AUX errlog.log, found that the day of the soft reset record, the time with the report of the BD_STATUS alarm time is consistent.
2013-03-10 [18:31:00] 0x0a 0xf0000010 0x00000001
This shows that the AUX reported BD_STATUS because a soft reset occurred.
5, then why PIU reported BD_STATUS, and what is the connection with AUX? After inquiring the information, we know the reason that the PIU of 1500 network element is sent to the master control through AUX, so the soft reset of AUX will cause PIU to report BD_STATUS alarm at the same time.
Suggestions and Summary
None
The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain the reproduction! Our company specializes in Huawei SDH optical transmission equipment,SDH transmission equipment sales.