OSN1500 master is backing up data causing backup master activation to fail during upgrade
| 2025-11-21|Back

Description of the problem

When upgrading from V1R7 to V1R8SPC200, the OSN1500 network element in the current network encounters the problem of failing to activate the standby master. Using U2000V1R5 integrated DC tool, DC reports error: Failed to activate the card...


Processing

First through the DC tool log (located in the tkdll_log folder, xx-xxnemsg_20130403_024637.log log file. xx-xx is the network element NEID)

Check the specific failure reason and find the following error code:

[05:49:18.810447 51-60] send.

:cfg-reset-board:83,soft

[05:49:18.869820 51-60] recv.

NSERR_CFG_NEED_TO_BACKUP [05:49:18 869820 51-60] recv: failed! cmd:0x8106 error:0x9aab NSERR_CFG_NEED_TO_BACKUP

This indicates that the network element was doing a master board database backup operation at that time. Since the master board is prohibited from being reset during this operation. This is because a reset will result in incomplete data on the master board after reboot. There are many service configuration loss problems in the current network caused by abnormal reset of the master control.


Root Cause

Master is synchronizing master and backup causing activation failure


Solution

Since the software loading step is normal, the current master board already has the new software, just not activated. (In fact, activation of other boards besides the main master can be equated to a reset board operation.)

So check the backup status of the master control and continue the activation operation of the upgrade task after the backup status is OK.

The upgrade is completed normally.


Recommendations and Summary

There are several cases of this problem in the same place. Some of them are due to the fact that before upgrading, the backup status of the master database was not checked as required by the upgrade guide, and some of them are due to the abnormality of the master board itself, and the backup status has been kept in the unfinished state (this situation needs to be solved by changing the board).

DC tool error message only tells the error in which step, if you want to know the details of the error message returned by the network elements need to check the DC log. This can be more in-depth understanding of the root cause of the problem.



The technical information related to this chapter and the SDH equipment troubleshooting process are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), and are reproduced with permission! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix OSN1500_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH Transmission Equipment Sales
Supply Optix OSN1500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板