MSTP+OSN3500 devices automatically generate an error tunnel when configuring a tunnel
| 2025-11-21|Back

Description of the problem

MSTP+ device OSN3500, version V2R11SPC200, host version 5.21.31.35, U2000 network management version U2000V1R6C02SPC300. as shown in the figure, in the configuration of the tunnel, the device from the network element 9-22704 to create ingress tunnel, fill in the source end LSRID as 1.11.177.67, it shows that the creation is successful, but when you query the tunnel list, there are two tunnels, one is deployed, the source LSRID is 1.11.177.67, which is the correct tunnel that needs to be created, and the other is deployed, the source LSRID is 1.11.177.191, which is the wrong tunnel that is automatically generated. tunnel, and there is no network element with the LSRID 1.11.177.191 on the network management, resulting in the customer never being able to successfully create a service.


Process

1、Main control board abnormality

2、Network management abnormality

3、Database abnormality


Root cause

When replacing the master control, the database is restored directly without changing the LSRID first, resulting in inconsistency between the system parameter area and the database LSRID.


Solution

1, suspect that the main control board problems, the main backup main control board inverted, reconfigure the tunnel failure remains

2、Suspect network management problems, use command line tools to configure tunnel, or will generate the wrong tunnel.

3、Check the database status is normal

4, respectively, the collection of network management data and device data to find the R & D analysis, the results of the analysis is the network management configuration source node is 1.11.177.67, the host node is 10.11.178.23 tunnel and the source node is 10.11.178.23, the host node is 1.11.177.67 tunnel 1.11.177.67 when the 1.11.177.67 became 0.0.0.0, requiring the device to continue analyzing. The device platform analysis found that the device's system parameter area and the database LSRID (GCPNODEID) are inconsistent, and need to re-issue LSRID 1.11.177.67 on the network management.

5, in the network management to re-issue LSRID1.11.177.67 did not recover, because the network management of the LSRID and the database LSRID is the same, so the network management will not send the data down, with the command line for the next LSRID1.11.177.67, configuration of the business back to normal.


Suggestions and Summary

When replacing the master without first changing the LSRID and directly restoring the database, the LSRID in the system parameter area is still that of the original master, but the LSRID in the database is new, so it leads to inconsistency between the system parameter area and the database LSRID.

Subsequent problem avoidance methods:

A, dual master respectively replaced, in accordance with the correct steps to change the board, you need to pay attention to ensure that the main backup master database backup is successful, the next step.

B, single master directly replace, change the single board before you need to set the new master's gcpnodeid the same as the original master, and then directly replace the single board.


The relevant technical information and SDH equipment troubleshooting procedures in this chapter are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited ( www.opticaltrans.com), please retain! Our company specializes in the sale of Huawei SDH optical transmission equipment, SDH transmission equipment.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板