Description of the problem
The OSN7500II device needs to expand a 10GE device, and the counterpart device is the N1PEX2 single board of OSN3500. Get a new N1EX2 single board from the customer, insert it in the empty slot, adjust the optical power so that the received optical power is within the range of the single board; create a Tunnel from OSN7500II to OSN3500, configure OAM, OSN3500 reports MPLS_TUNNEL_LOCV alarm, OSN3500 reports MPLS_TUNNEL_LOCV alarm, OSN7500II reports MPLS_TUNNEL_LOCV alarm, OSN3500 reports MPLS_TUNNEL_LOCV alarm, OSN3500 reports MPLS_TUNNEL_LOCV alarm, OSN3500 reports MPLS_TUNNEL_LOCV alarm. LOCV alarm, OSN7500II has no alarm.
Processing
The following problems are MPLS_TUNNEL_LOCV alarms.
1. In manual detection mode, the MPLS OAM attributes configured by the two end network elements do not match, such as detection message type or detection message period.
2. Severe network congestion.
3. Single board failure.
4. Physical link failure.
Root cause .
N/A
Solution
1. Query the MPLS OAM attributes and find that the OAM protocols are all Y.1711, and the message detection types are all FFD/3.3ms, eliminating reason 1.
2. The link belongs to the expansion of the new link, does not carry any other services, there is no congestion.
3. The physical link receives normal optical power, and the connected ports are configured with Layer 3 attributes, IP address 10.125.40.1/10.125.40.2, in the same network segment, IP address in the same network segment, to rule out the cause of reason 4.
4. Query ARP list, found that the OSN7500II device N1EX2 single board port port IP, MAC information, but the OSN3500 device N1PEX2 single board no information on the opposite end; due to the N1EX2 single board is obtained from the customer that suspects that the single board has a problem, query the single board software version V5.04, and the device has the single board software version V2.15 does not comply with the query device version V200R011C02 supporting version, found that the new single board software version is too high, and the device does not match.
5. In accordance with the guidance document, the single board degradation, reconfigure the business, no problems found, the business is normal!
Recommendation and summary
In the expansion, often need to add a new single board, in the use of the new single board, you need to pay attention to the single board software version and equipment software version matching problems, version mismatch, it is likely to lead to the business does not work!
This chapter of the relevant technical information and SDH equipment troubleshooting process by the Shenzhen Optical Transmission Network Technology Limited collection ( www.opticaltrans.com), reproduced please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Chinese
English