18529092692

Home >> News
News
OSN1500 Q2CXL system control board reports BD_TATUS and HSC_UNAVAIL.
| 2025-11-21|Back

OSN1500 SSQ2CXL single board provides timing information to other single boards in the system, carries out SDH signal processing, completes the scheduling of services between line boards and branch boards, and accomplishes the communication with other single boards in the system as well as the configuration management of other single boards, etc. It supports standard optical interfaces of I-1, S-1.1, L-1.1, L-1.2 and Ve-1.2. Supports the standard optical interfaces of I-1, S-1.1, L-1.1, L-1.2, and Ve-1.2, of which the characteristics of the I-1, S-1.1, L-1.1, and L-1.2 optical interfaces comply with the ITU-T G.957 recommendations, and the optical interface of Ve-1.2 is a Huawei customized standard.Supports the use and monitoring of SFP pluggable optical modules, facilitating the maintenance and upgrade of optical modules. Supports optical module information detection and query.Supports laser on and off settings and laser automatic shutdown function.Support inner loopback and outer loopback functions at the optical port level.Support soft reset and hard reset, soft reset does not affect the service.Support soft reset and hard reset, soft reset does not affect the service.

Description of Failure Causes

On-site inspection found that the temperature of the single board of the network element is particularly high, and it has reached 80 degrees, which may cause the single board to be out of position due to the high temperature, and BD_TATUS and HSC_UNAVAIL are reported.
Explanation: You can query the temperature of the single board through the network management to locate it remotely.


Products

OptiX OSN 1500

Fault Category

  • Other
  • BD_STATUS
  • HSC_UNAVAIL

Description

The OptiX OSN 1500 network element reported BD_STATUS alarms at logical slots 4, 80, and 82, and HSC_UNAVAIL alarms were reported after resetting the CXL board, with the alarm parameter "0x81 0x01 0x50". After a period of recovery, the network element reports BD_STATUS alarm again, and the service is not affected.

Operation steps

  1. Check the fan, it is running normally.
  2. Remove the dust net and find that there is a lot of dust, clean it up and reinsert it, the problem is solved.

Reference information

Clean the dust net regularly, it is recommended to clean it once a month.

The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com). Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to telephone consultation!


Sales Optix OSN1500_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN1500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板