The OSN3500 EGT2 board cannot be configured with both VC-3 and VC-4 services.
| 2025-11-21|Back

The OSN3500 EGT2 single boards are available in feature versions N1 and N2. the single boards are Ethernet transparent transmission single boards, which are mainly used to solve the telecommunication application areas such as Ethernet service access, bandwidth management, etc. The single boards support functions and features such as LCAS and test frame. The single board supports functions and features such as Ethernet service transparent transmission, LCAS and test frame. The single board consists of an Ethernet access module, a mapping module, an interface conversion module, a logic control module, a clock module, and a power module. The faceplate of the veneer has veneer indicators, interfaces, barcodes, and laser security levels. There are no dial codes or jumpers on the veneer for veneer setup. The single board supports a variety of Ethernet functional features such as LCAS, LPT, etc. and can be configured according to actual needs.

An error occurs when configuring the VC-3 service on the EGT2 veneer that has been configured with the VC-4 service, and the fault is eliminated after the service type is uniformly configured.

Products

  • OptiX OSN 7500
  • OptiX OSN 9500

Fault category

Ethernet Failure

Phenomenon Description

When a customer configures a VC-3 service on the second port of an EGT2 board that already has a VC-4 service, the network management prompts that the service cannot be configured.

Cause Analysis

VC-3 and VC-4 services cannot be configured simultaneously on EGT2, EGT6, and single boards that support RPR features.
  • On the same port, EGT2 and the single board supporting the RPR feature cannot configure VC-3 and VC-4 services at the same time, regardless of whether the same VCTRUNK is used or not.
  • The six GE ports of the EGT6 single board correspond to the six VCTRUNK ports one by one. the six GE ports are divided into three groups in terms of data mapping (DM) chips, as shown in Table 1, and different types of services can be configured for the VCTRUNKs in different groups.
    Table 1 Correspondence between EGT6 single board group number and VCTRUNK
    Group VCTRUNK No.
    1 1 & 2
    2 3 & 4
    3 5 & 6

Procedure

  1. After the service type (VC-3 or VC-4) is configured in a uniform manner, the fault is eliminated.

Reference Information

The OptiX OSN 7500 devices support the RPR feature on single boards such as EMR0, EGR2, and so on.


The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply OSN3500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板