OSN3500 VCTRUNK timeslot loss causes RPR ring inversion
| 2025-11-21|Back

OSN3500 RPR single board has and only has 2 VCTRUNKs on SDH side, for VC4 level service, VCTRUNK1 must be bound to odd (1, 3, 5, 7, 9, 11, 13, 15) time slot number among 1 to 16 time slots, and VCTRUNCK2 must be bound to even (2, 4, 6, 8, 10, 12, 14, 16) time slot number. For VC3 level service, VCTRUNK1 can only select VC4-1 for "optional resources" and VC3-1 and VC3-2 for "optional time slots"; VCTRUNK2 can only select VC3-1 and VC3-2 for "optional resources"; VCTRUNK2 can only select VC3-1 and VC3-2 for "optional resources". For VCTRUNK2, "optional resources" can only be selected from VC4-2, and "optional time slots" can only be selected from VC3-1 and VC3-2. When configuring, you need to ensure that all nodes on the entire RPR ring network have the same bandwidth for the single-ring configuration, and you need to follow the above binding principles for VCTRUNK binding.

OptiX OSN 1500A and OSN 1500A

  • OptiX OSN 1500A/1500B
  • OptiX OSN 2500
  • OptiX OSN 3500 II
  • OptiX OSN 3500
  • OptiX OSN 7500

Fault Category

  • RPR
  • Ethernet Fault
  • RPR_PS_CHANGE

Phenomenon Description

The services of the RPR ring network are connected, and the RPR_PS_CHANGE alarm is reported, and the RPR ring network is inverted.

Cause Analysis

The probable cause of the above failure phenomenon is the loss of VCTRUNK time slot.

Procedure

  1. Enable the LCAS protocol of the corresponding connected Ethernet board to detect whether each time slot works normally. If the time slots are corrupted, the LCAS protocol deletes them from VCTRUNK.
  2. Query the actual bound timeslots of VCTRUNK and the configured timeslots, if they do not match, the damaged VC4 timeslots have been deleted by the LCAS protocol. The alarm disappears and the fault is eliminated.

The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply OSN3500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板