OSN1500_Huawei SDH Transmission Equipment Pipe Reporting ETH_LOS Alarms
| 2025-11-21|Back

After OSN1500 adds and removes cross-connections for FE services, ETH_LOS alarms are reported on EFS4 boards at some sites. The fault can be resolved by disabling unused MAC ports.

Products

OptiX OSN1500

Failure Category

  • Alarm Performance
  • ETH OAM
  • Ethernet Fault
  • ETH_LOS

Phenomenon Description

OSN1500 deploys some FE services between sites in the U2000 network management center as needed, and adds and deletes some cross-connections for FE services. After the service provisioning is finished, ETH_LOS alarms are reported on the EFS4 single boards in some sites.

Cause Analysis

During the provisioning process, alarms appear after adding and deleting some FE services, so the fault can be localized to these FE services.

Operation Steps

  1. Check the FE service between two sites as an example, and find that after adding the FE service normally, the corresponding EFS4 board does not report the ETH_LOS alarm.
  2. Check the paths of the FE services that report ETH_LOS alarms and find that these paths have been deleted during the provisioning and maintenance process, and in fact these paths no longer exist.
  3. Log in to T2000 network management and select "Network Element Manager". Select the FE service corresponding to the ETH_LOS alarm, check the port properties of the corresponding EFS4 board, and find that the "Port Enable" setting of the deleted service is set to "Allow", but at this time, there is no access to the customer-side signals, so the board reports the ETH_LOS alarm incorrectly. ETH_LOS alarm is reported.
  4. Set the "Port Enable" corresponding to the deleted service to "Disable", check and confirm the alarm again, and the ETH_LOS alarm disappears.
  5. Check all the Ethernet boards with ETH_LOS alarms, and find that the failure is caused by the same reason. Set "Port Enable" to "Disable" on the board where the Ethernet service has been deleted, and the ETH_LOS alarm disappears.


The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to telephone consultation!


Sales Optix OSN1500_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN1500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板