The basic attributes of an SDH interface define information about its physical layer, including port mode, encapsulation type, and maximum packet length.

Prerequisites

Network administrator privileges of "Operator Group" and above.

Steps

  1. Click a network element in the Element Manager and select "Configuration > Interface Management > SDH Interface" in the function tree.
  2. Select the single board to be configured.
  3. Set the corresponding parameters as required. see Table 1 for the parameter descriptions of the basic attributes of the SDH interface.


    Description:

    PTN 3900/3900-8/1900: Pay attention to the setting parameters:

    • When the "Port Mode" is Layer 1, the "Encapsulation Type" is not supported, and you can access channelized STM-N service and Fractional E1.
    • When "Port Mode" is Layer 2, "Encapsulation Type" only supports ATM, and ATM services can be accessed at this time.
    • When "Port Mode" is Layer 3, "Encapsulation Type" can select Null or PPP; if Null is selected, the interface will not enable PPP protocol, which can reduce the load on the device; if PPP is selected, the interface can access MPLS or IP services. If you choose PPP, the interface can access MPLS or IP services.
    • The value of "Maximum packet length (bytes)" of the network side interface must be greater than or equal to 960, because the maximum length of DCN message is 960, and when the value of "Maximum packet length (bytes)" is less than 960, it may cause the DCN message in the receiving direction to be lost. DCN messages in the receive direction may be lost if the value of "Maximum packet length (bytes)" is less than 960.


  4. Optional: Select a port that can be opened in the window below to view its associated services and the logical port to which it belongs.
  5. Click "Apply" to bring up the "Operation Result" dialog box, indicating that the operation is successful.
  6. Click Close.

The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales PTN1900_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply PTN1900_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板