Technical indicators

Device subframe specifications include subframe dimensions, weight, and maximum power consumption.

The technical specifications for the OptiX OSN 3500 subrack are shown in Table 1.

Table 1 OptiX OSN 3500 Subrack Specifications
Dimensions Weight
497mm (W) x 295mm (D) x 722mm (H) 23kg (net weight of subrack, excluding veneer and fan)

The maximum power consumption of the OptiX OSN 3500 subrack is shown in Table 2.

Table 2 Maximum power consumption of OptiX OSN 3500 subracks
Subrack type Maximum power consumptiona Insurance capacity Typical Configuration
Typical Power Consumption

Single Board Configuration at Typical Power Consumption

OptiX OSN 3500 Common Subracks 720W 20A 442W
  • 2 blocks of N1SLD64 (S-64.2b, LC)
  • 2 blocks of N2SLQ4 (S-4.1, LC)
  • 2 pieces of N1SLQ16 (L-16.2, LC)
  • 2 pieces of N1SLH1 (S-1.1, LC)
  • 4 blocks of N1OU08
  • 2 blocks of N2EGT2
  • 2 blocks of N1SXCSA
  • 1 block N4GSCC
  • 1 N1AUX
  • 2 N1PIU
OptiX OSN 3500 Enhanced Subracks 1100W 32A 520W
  • 2 blocks of N1SLD64 (S-64.2b, LC)
  • 2 blocks of N2SLQ4 (S-4.1, LC)
  • 4 pieces of N1SLQ16 (L-16.2, LC)
  • 2 blocks of N1SLH1 (S-1.1, LC)
  • 4 blocks of N1OU08
  • 2 blocks of N4EGS4
  • 2 blocks of N1SXCSA
  • 1 block N4GSCC
  • 1 N1AUX
  • 2 N1PIUA
OptiX OSN 3500 III Subracks 2300W 63A 516W
  • 2 blocks of N1SLD64 (S-64.2b, LC)
  • 2 blocks of N2SLQ4 (S-4.1, LC)
  • 4 blocks of N1SLQ16 (L-16.2, LC)
  • 2 blocks of N1SLH1 (S-1.1, LC)
  • 4 blocks of N1OU08
  • 2 blocks of N4EGS4
  • 2 blocks of N1SXCSA
  • 1 block N4GSCC
  • 1 block N1AUX
  • 2 N1PIUB
a: The maximum power consumption of the subrack indicates the maximum power consumption configuration that the subrack can withstand and the maximum heat dissipation capability of the subrack. Typical configurations for actual applications consume much less power than this value.
Description:

The default maximum power consumption value of the device is 1100W, if you need to use 2300W, you need to set it through the network management.

The maximum power consumption when the cabinet is fully configured is equal to the sum of the maximum power consumption of all the subracks configured in the cabinet and the maximum power consumption of the other configurations of the cabinet.

For transmission equipment, power consumption is essentially all converted to heat consumption. Therefore, the thermal consumption (BTU/h) value of the equipment can be converted with the power consumption (W) value, and the conversion formula is: thermal consumption (BTU/h) = power consumption (W) ÷ 0.2931 (Wh).

The expected reliability metrics for OptiX OSN equipment are shown in Table 3.

Table 3 Equipment Reliability Estimates
System availability System mean time to repair (MTTR) System Mean Time Between Failures (MTBF)
0.9999953 1 hour 24.05 years

The technical information in this chapter and the related SDH equipment troubleshooting procedures are provided by Shenzhen Optical Transmission Network Technology Co. Huawei SDH optical transmission equipment, SDH transmission equipment sales phone: 13430988088 Welcome to call!


Sales Optix Metro3500_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH transmission equipment sales
Supply Optix Metro3500_Troubleshooting_Installation and testing_Technical indicators_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板