Protection requirements

18529092692

OSN3500 SSN5EFS0 8-way Fast Ethernet Processing Board with Switching
  • OSN3500 SSN5EFS0 single board has four functional versions: N1, N2, N4 and N5, N1EFS0, N2EFS0 and N4EFS0 single boards have been discontinued.N5EFS0 supports the single board compatible replacement function, which can replace N4EFS0, N2EFS0 and N1EFS0.

  • Consultation hotline:
    18529092692
    Product Introduction
    Products
    Huawei SDH equipment OSN3500 SSN5EFS0 technical parameters

    OptiX OSN3500 EFS0 Single Board Functions and Features

    OSN3500 SSN5EFS0价格

    OSN3500 SSN5EFS0 functions and features

    Table 1 Huawei SSN5EFS0 single-board functions and features

    Functions and features Description
    Basic functions Processing 8-channel FE services
    Interface type
    • Use with ETF8 to support 10Base-T/100Base-TX and meet IEEE 802.3u standard.
    • Support 100Base-FX/LX/VX/ZX with EFF8 to meet IEEE 802.3u standard.
    • N5EFS0 works with ETF8A to support 100Base-TX and meets the IEEE 802.3u standard.
    • N5EFS0 works with EFF8A to support 100Base-FX/LX and meets the IEEE 802.3u standard.
    In conjunction with the outgoing board
    • Use with ETF8 to realize 8-way FE telecom signal access.
    • Work with EFF8 to realize 8-channel FE optical signal access.
    • Match with ETS8 and TSB8 to realize 8-channel FE electrical signal TPS protection.
    • N5EFS0 can also cooperate with ETF8A to realize 8-channel FE electrical signal access.
    • N5EFS0 can also cooperate with EFF8A to realize 8-channel FE optical signal access.
    Interface Characteristics Working Mode
    • FE electrical interface: supports self-negotiation, 100M full-duplex, 100M half-duplex, 10M full-duplex, 10M half-duplex.
    • FE optical port: supports 100M full duplex.
    • When N5EFS0 is used with ETF8A, only self-negotiation and 100M full duplex are supported.
    Port Flow Control Methods Self-negotiation Supported (not supported on FE optical ports)
    Non-self-negotiation Support (non-self-negotiation flow control is not supported when used with EFF8 single board)
    Port status query/configuration Supported
    Interface type query Support
    Optical power threshold setting Not supported
    Pluggable Optical Module Not supported
    Service Type EPL Supports PORT-based transparent transport.
    EVPL
    • Supports EVPL service with shared PORT.
    • Supports EVPL service with shared VCTRUNK.
      • VLAN tag isolation based
      • MPLS label-based isolation
    • Supports up to 4096 LINK services.
    EPLAN

    N4EFS0/N5EFS0 supports EPLAN services based on IEEE 802.1d MAC bridge.

    • Maximum support 2K blacklists and 2K static MAC addresses, shared 2K. blacklists on N5EFS0 boards only support destination MAC address checksums, not source MAC address checksums.
    • Support source MAC address self-learning function, MAC address table size is 16K, support MAC address aging time setting and query.
    • Supports static MAC routing configuration.
    • N4EFS0/N5EFS0 supports dynamic MAC address query.
    • The maximum number of VBs supported is 16, and the maximum number of logical ports per VB is 30.
    • Supports querying the number of actual learned MAC addresses by VB+VLAN or VB+LP.
    EVPLAN
    • Supports data isolation based on VB+VLAN method.
    • The maximum number of VBs supported is 16, and the maximum number of logical ports per VB is 30.
    • Supports the setting of up to 4096 VLAN services.
    • Supports EVPLAN services based on IEEE 802.1q Virtual Bridge.
    • N5EFS0 also supports EVPLAN services based on IEEE 802.1ad Provider Bridge.
    Service Specifications Ethernet Data Frame Format IEEE 802.3 Supported
    Ethernet II Supported
    IEEE 802.1 q/p Supported
    Frame Length Range Support 1518Byte~9600Byte message length setting, support Jumbo frames up to 9600Byte.
    Mapping Method VC-12, VC-3, VC-12-Xv (x≤63), VC-3-Xv (x≤12)
    Encapsulation Format HDLC Not supported
    LAPS Not supported
    GFP-F Supported
    MPLS Technology Supported
    VLAN Technology Supports 4094 VLAN tags, VLAN technology meets IEEE 802.1q/p standard.
    Maximum Uplink Bandwidth
    • The maximum uplink bandwidth of N1EFS0 is 622Mbit/s.
    • The maximum uplink bandwidth of N2EFS0/N4EFS0/N5EFS0 is 1.25Gbit/s.
    • Support slot bandwidth adaption.
    Maximum Binding Bandwidth

    N1EFS0: 12xVC-3 or 63xVC-12+9xVC-3

    N2EFS0/N4EFS0/N5EFS0: 24xVC-3 or 126xVC-12+18xVC-3

    VCTRUNK Specifications
    Quantity:
    • The number of VCTRUNK for N1EFS0 is 12.
    • The number of VCTRUNK for N2EFS0/N4EFS0/N5EFS0 is 24.

    Configuration Features:

    • After a VC channel of each level is used by one VCTRUNK binding, other VCTRUNKs can no longer be used.
    • VCTRUNK1 to VCTRUNK12 are required to be bound when the bandwidth of N2EFS0/N4EFS0/N5EFS0 slots is 622M bit/s.
    • VCTRUNK1 to VCTRUNK12 can only bind low-order services of 1 to 4 VC-4 channels, and VCTRUNK13 to VCTRUNK24 can only bind low-order services of 5 to 8 VC-4 channels.
    • The two VC-4s, 4 and 8, can be bound to both VC-3 and VC-12 channels, while the other VC-4s can only be bound to VC-3 channels.
    • Each VCTRUNK can bind up to 12 VC-3s or 63 VC-12s.
    • The same VCTRUNK can only be bound to one level of channel, it cannot be bound to both VC-12 channels and VC-3 channels.
    Protection Methods TPS N1EFS0 is not supported, N2EFS0/N4EFS0/N5EFS0 are supported.
    BPS Not supported
    PPS Not supported
    DLAG Not supported
    LAG

    N1EFS0 does not support link aggregation, N2EFS0/N4EFS0/N5EFS0 support manual link aggregation and load sharing. Meets IEEE 802.3ad and IEEE 802.1AX standards.

    LCAS

    N1EFS0/N2EFS0 are not supported.

    N4EFS0/N5EFS0 is supported to realize dynamic increase, dynamic decrease and protection function of bandwidth, which meets ITU-T G.7042 standard.

    LPT N1EFS0/N2EFS0 support point-to-point LPT, and N4EFS0/N5EFS0 support point-to-point LPT and point-to-multipoint LPT, meeting Huawei's internal protocol standards.
    STP/RSTP Supports the broadcast message suppression function and Rapid Spanning Tree Protocol (RSTP), meeting the IEEE 802.1w standard.
    MSTP does not support
    Synchronization Synchronous Ethernet Not supported
    1588v2 Not supported
    Maintenance Features ETH OAM
    • N1EFS0 and N2EFS0 are not supported.
    • N4EFS0/N5EFS0 supports CC, LB, and LT to meet the IEEE 802.1ag standard; it supports OAM_Ping to meet Huawei's internal protocol standard.
    • N4EFS0/N5EFS0 supports OAM auto-discovery, remote loopback, fault detection, and link performance monitoring, which meets the IEEE 802.3ah standard; it supports self-loop detection, which meets Huawei's internal protocol standard.
    Test Frames
    • N1EFS0/N2EFS0 supports test frames under Ethernet bearer mode.
    • N4EFS0/N5EFS0 support test frames in Ethernet/GFP bearer mode.
    Response Ping Function

    Does not support

    Port Mirroring N1EFS0/N2EFS0/N4EFS0 do not support, N5EFS0 supports inbound port mirroring.
    Loopback Capability Ethernet port PHY layer Supports inner loopback
    Ethernet port MAC layer Supports inner loopback
    VC-4 level Not supported
    VC-3 level N1EFS0/N2EFS0/N4EFS0 support inner loopback and outer loopback, N5EFS0 does not.
    VC-12 level Not supported
    RMON Port-level Ethernet performance monitoring is supported.
    Soft Reset N1EFS0/N2EFS0 support soft reset, and soft reset interrupts service.N4EFS0/N5EFS0 support soft reset, and soft reset does not affect service. When N4EFS0/N5EFS0 is compatible to replace N1EFS0/N2EFS0, soft reset is supported and soft reset does not affect the service.
    Hard reset Support
    Alarm and Performance Provides rich alarms and performance events for easy device management and maintenance.
    QoS
    • Supports CAR with a granularity of 64kbit/s.
    • N1EFS0 supports service classification based on PORT, PORT+VLAN, and PORT+VLAN PRI.

    • N2EFS0, N4EFS0 and N5EFS0 support flow classification based on PORT, PORT+VLAN, PORT+VLAN+VLAN PRI.
    • N5EFS0 also supports PORT+SVLAN-based flow classification.
    IGMP Snooping Protocol Enablement Supports
    Port Aging Time Support for
    Fast Leave

    N1EFS0, N2EFS0 and N4EFS0 are not supported.

    N5EFS0 is supported.

    Unknown multicast message discard

    Not supported by N1EFS0, N2EFS0 and N4EFS0.

    N5EFS0 supports it.

    Static multicast table entries Not supported
    Hub/Spoke

    Not supported by N1EFS0, N2EFS0.

    N4EFS0 and N5EFS0 are supported.

    Traffic Control Port-based IEEE 802.3x flow control is supported.
    Description:

    Only EPL services support port-based flow control.

    Traffic Monitoring N5EFS0 supports port and VCTRUNK based traffic monitoring.

    The SSN5EFS0 single board supports Layer 2 switching, MPLS, multicast, and other functions and features.

    The specific functions and features of the SSN4EFS0 single board are shown in Table 1.




    Huawei SSN5EFS0 Purchase Price_Product Description_Hardware Description_Technical Parameters_Product Features-Huawei SDH Transmission Equipment Sales
    Supply Optix OSN3500 SSN5EFS0 Quote_Agent Price_Sales Manufacturer_Product Supplier-Huawei SDH Transmission Equipment Sales
    Online Ordering
    Contact Us
    Name:Mr Zhang
    Phone:18529092692
    Tel:18529092692
    Email:info@opticaltrans.com
    Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
    Contact
    18529092692
    Phone:18529092692
    Email:info@opticaltrans.com
    Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
    Follow Us
    Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
    Copyright © 2025 Otrans all right reserve XML