Optix OSN8800 TN54NS3 40G Line Service Processing Board
  • The Optix OSN8800 TN54NS3 single board belongs to the line class of single boards and realizes the interconversion of the following signals: 32 x ODU0/32 x ODUflex/16 x ODU1/4 x ODU2/1 x ODU3

    <->1 x OTU3, 4 x ODU2e<->1 x OTU3e or 256 x VC-4&. lt;->1 x OTU3.

Consultation hotline:
18529092692
Product Introduction

Products

Huawei OTN Line Services OSN8800 TN54NS3T01 Technical Parameters Description

The TN54NS3T01 single board belongs to the line class of single boards, realizing the interconversion of the following signals: 32 x ODU0/32 x ODUflex/16 x ODU1/4 x ODU2/1 x ODU31 x OTU3, 4 x ODU2e1 x OTU3e, or 256 x VC-41 x OTU3. OTU3/OTU3e are DWDM standard wavelengths in accordance with ITU-T recommendation G.694.1. G.694.1 recommendation for DWDM standard wavelengths.TN52NS3/TN54NS3/TN55NS3 support mixed transmission of ODU0, ODU1 and ODU2/ODU2e.TN56NS3 support mixed transmission of ODU0/ODU1/ODU2/ODU2e/ODUflex/VC-4.TN55NS3/ TN56NS3 uses coherent reception technology and is applied to coherent systems.

For the TN54NS3 single board:

  • When configured as a 40Gbit/s multirate-2km optical module. the WDM side does not support OTU3e and the backplane side does not support ODU2e.

  • When configured as 800ps/nm-C-band-tunable-wavelength-ODB-PIN, 800ps/nm-C-band-tunable-wavelength-DQPSK-PIN, or 800ps/nm-C-band-tunable-wavelength-nDQPSK-PIN optical modules, there is no restriction mentioned above.

TN11NS3/TN52NS3/TN54NS3/TN55NS3/TN56NS3 Single Board Application Scenario 1: Interconversion between 4-channel ODU2/ODU2e signals and 1-channel OTU3/OTU3e signals is realized

Figure 1 Application scenario 1 of NS3 single board in WDM system

OSN8800 TN54NS3T01价格

Description:

TN54NS3/TN55NS3/TN56NS3 need to set the "Single Board Mode", and the "Single Board Mode" of this application scenario is: "Normal Line Mode".

TN52NS3/TN54NS3/TN55NS3/TN56NS3 Single Board Application Scenario 2: Mutual Conversion between 16-channel ODU1 Signal and 1-channel OTU3 Signal

Figure 2 Application scenario 2 of NS3 single board in WDM system

OSN8800 TN54NS3T01价格

Description:

  • TN54NS3/TN55NS3/TN56NS3 need to set the "Single Board Mode", and the "Single Board Mode" of this application scenario is: "Normal Line Mode".

  • TN52NS3 mapping path is: ODU1->ODU2->ODU3.

  • TN54NS3/TN55NS3/TN56NS3 mapping path is: ODU1->ODU3.

TN52NS3/TN54NS3/TN55NS3/TN56NS3 Single Board Application Scenario 3: Realize the interconversion between 32 ODU0 signals and 1 OTU3 signal

Figure 3 NS3 single board application scenario 3 in WDM system

OSN8800 TN54NS3T01价格

Description:

  • This scenario is only supported by TN52NS3/TN54NS3/TN55NS3/TN56NS3 in OptiX OSN 8800.

  • TN52NS3/TN54NS3/TN55NS3/TN56NS3 need to set the "Single Board Mode", and the "Single Board Mode" of this application scenario is: "Normal Line Mode".

  • The mapping path of TN52NS3 is: ODU0->ODU1->ODU2->ODU3.

  • The mapping path of TN54NS3/TN55NS3 is: ODU0->ODU1->ODU3.

  • When the ODU time slot mode is configured as "Auto Continuous", the mapping path of TN56NS3 is: ODU0->ODU1->ODU3; when the ODU time slot mode is configured as "Auto Random", the mapping path of TN56NS3 is: ODU0->ODU1->ODU3. When the ODU time slot mode is configured as "Auto Random", the mapping path of TN56NS3 is: ODU0->ODU1->ODU3.

TN54NS3/TN55NS3/TN56NS3 Single Board Application Scenario 4: Realize the inter-conversion between 1 ODU3 signal and 1 OTU3 signal

Figure 4 NS3 single board application scenario 4 in WDM system

OSN8800 TN54NS3T01价格

Description:

TN54NS3/TN55NS3/TN56NS3 need to set the "Single Board Mode", and the "Single Board Mode" of this application scenario is: "Normal Line Mode".

When used with TSXL, the "Line Rate" parameter of TN54NS3/TN55NS3/TN56NS3 single board must be set to "Standard Mode".

TN54NS3/TN55NS3/TN56NS3 Single Board Application Scenario 5: Realize the electrical relay of 1 OTU3/OTU3e signal.

Figure 5 NS3 single board application scenario 5 in WDM system

OSN8800 TN54NS3T01价格

Description:

TN54NS3/TN55NS3 supports only relay mode in OptiX OSN 6800 subrack/OptiX OSN 8800 platform subrack/OptiX OSN 8800 universal platform subrack.

TN56NS3 supports only trunk mode in OptiX OSNOptiX OSN 8800 Universal Platform Subrack subrack.

Description:

TN54NS3/TN55NS3/TN56NS3 need to set the "Single Board Mode", which can be set to "Electric Relay Mode" or "Optical Relay Mode". For optical-layer ASON and electrical-layer ASON applications, setting "optical relay mode" and "electrical relay mode" has no effect on the system; for non-ASON applications, only "optical relay mode" can be set for end-to-end operation. For non-ASON applications, only "Optical Relay Mode" can be set for end-to-end management.

In this scenario, a pair of IN/OUT ports supports different input wavelengths and output wavelengths.

TN56NS3 Application Scenario 6: Realizing the interconversion between ODUflex signal and OTU3 signal

Figure 6 Application Scenario 6 of NS3 single board in WDM system

OSN8800 TN54NS3T01价格

TN56NS3 Application Scenario 7: Realizing the interconversion between VC-4 signals and OTU3 signals

Figure 7 NS3 single board in WDM system Application Scenario 7

OSN8800 TN54NS3T01价格

Description:

VC-4 can be mapped to ODU1 or ODU2.

When the single board is inserted in T64 subrack, it supports maximum 128xVC-4; when it is inserted in T32/T16 subrack, there is no such limitation.

When accessing SDH service, the single board does not support the time slot mode of "Auto Continuous", but only supports the mode of "Auto Random", so the single board that supports the mode of "Auto Random" should be used for docking. When docking, you need to use a single board that supports "Auto Random" mode.

TN52NS3/TN54NS3/TN55NS3/TN56NS3 Application Scenario 8: Realization of Hybrid Transmission Scenarios

Figure 8 NS3 single board in WDM system Application Scenario 8

OSN8800 TN54NS3T01价格

Description:

The IN/OUT port supports hybrid transmission of ODU0, ODU1, ODU2/ODU2e, ODUflex, and VC-4 with a maximum bandwidth of 40 Gbit/s. Only the TN56NS3 supports hybrid transmission of ODUflex and VC-4.

Single boards with different time slot configuration methods cannot be docked. The "ODU time slot configuration mode" parameter settings of the line boards at the two sites of the up and down services must be the same, and when the TN56NS3 board is docked with a board that does not support the setting of the "ODU time slot configuration mode" parameter, the "ODU time slot configuration mode" needs to be set to "Auto Continuous". When the TN56NS3 board is interfaced with a board that does not support the setting of "ODU time slot configuration mode" parameter, the "ODU time slot configuration mode" needs to be set to "Auto Continuous". For example, when TN56NS3 is interfaced with TN55NS3, since TN55NS3 does not support the setting of "ODU Slot Configuration Mode" parameter, the "ODU Slot Configuration Mode" parameter of TN56NS3 must be set to "Auto Continuous".

Only TN56NS3/TN54HUNS3 supports the setting of "ODU time slot configuration mode" parameter.


OSN8800 TN54NS34OG line service processing board Functions and Features

The NS3 board supports the functions and features of layer crossing, OTN interface, ESC, etc. The TN56NS3 board supports the mixed transmission of OTN and SDH services.

The NS3 single board supports line mode and trunk mode, and the functions and features are shown in Table 1 and Table 2 respectively.

Description:

  • Only OptiX OSN 8800 supports ODU0/ODU3.

  • Only the TN54NS3/TN55NS3/TN56NS3 support trunk mode.

  • For the TN54NS3 single board:

    • When configured as a 40Gbit/s multirate-2km optical module, OTU3e is not supported on the wavelength division side and ODU2e is not supported on the backplane side.

    • When configured as 800ps/nm-C-band-tunable-wavelength-ODB-PIN, 800ps/nm-C-band-tunable-wavelength-DQPSK-PIN, or 800ps/nm-C-band-tunable-wavelength-nDQPSK-PIN optical modules, there is no restriction mentioned above.

  • Only the TN56NS3 supports SDH-related features and functions: SDH overhead, physical layer clocking (OCS), electrical layer ASON (SDH), SDH protection, and VC-4 channel loopback.

Table 1 NS3 Single Board Functions and Features (Line Mode)

Functions and CharacteristicsDescription
Basic Functions

The NS3 supports the conversion of the following signals:

  • TN11NS3.

    • 4xODU21xOTU3/OTU3e

    • 4xODU2e1xOTU3e

  • TN52NS3.

    • 32xODU0/16xODU1/4xODU21xOTU3/OTU3e

    • 4xODU2e1xOTU3e

  • TN54NS3/TN55NS3.

    • 32xODU0/16xODU1/4xODU21xOTU3/OTU3e

    • 4xODU2e1xOTU3e

    • 1xODU31xOTU3

  • TN56NS3.

    • 32xODU0/32xODUflex/16xODU1/4xODU21xOTU3/OTU3e

    • 4xODU2e1xOTU3e

    • 1xODU31xOTU3

    • 16xSTM-16/4xSTM-641xOTU3/OTU3e

TN52NS3/TN54NS3/TN55NS3 supports mixed transmission of ODU0, ODU1, ODU2 and ODU2e. TN56NS3 supports mixed transmission of ODU0/ODU1/ODU2/ODU2e/ODUflex/VC-4. When there is ODU2e in the mixed transmission signal, it must be encapsulated as OTU3e.

TN11NS3/TN52NS3/TN54NS3 single boards can perform dispersion compensation for signals accessed on the WDM side.

Crossover CapabilitySupport to realize service scheduling with crossover board.

OptiX OSN 8800:

  • TN52NS3: 32xODU0/16xODU1/4xODU2/4xODU2e

  • TN54NS3/TN55NS3: 32xODU0/16xODU1/4xODU2/4xODU2e/1xODU3

  • TN56NS3: 32xODU0/32xODUflex/16xODU1/4xODU2/4xODU2e/1xODU3/256xVC-4

Description:

The TN56NS3 single board supports a maximum of 128xVC-4 when plugged into the T64 subrack; there is no such limitation when plugged into the T32/T16 subrack.

OptiX OSN 6800:

  • TN11NS3: 4xODU2/4xODU2e

  • TN52NS3: 32xODU0/16xODU1/4xODU2/4xODU2e

OTN Function
  • WDM side supports OTU3/OTU3e interface.

  • Adopts ITU-T G.709 recommended frame format and overhead processing.

  • OTU3 layer: supports SM function.

  • ODUk (k=0, 1, 2, 3, flex) layer: supports PM and TCM functions, non-invasive monitoring functions for PM and TCM.

Description:

Only the ODU0 layer and ODUflex layer of the TN56NS3 single board support the TCM function and the non-intervention monitoring function of TCM.

SDH Service ProcessingSupports VC-12/VC-3/VC-4 services and VC-4-4c, VC-4-16c, VC-4-64c cascade services.
SDH Overhead HandlingSupported by TN56NS3 only:
  • Supports the processing of segment overhead for STM-16/STM-64 signals.

  • Supports processing of channel overhead (transparent transmission and termination).

  • Supports setting and querying of J0/J1/C2 bytes.

Description:

TN56NS3 only supports D4-D12 channel overhead processing, not D1-D3 channel overhead processing.

WDM Specifications

Supports DWDM specifications of ITU-T G.694.1.

Wavelength Tunable Function

Supports wavelength tunable optical modules. Realizable.

  • Wavelength division side optical signals are adjustable in the 40-wave range at 100 GHz interval in C-band.

  • The wavelength of the optical signal is adjustable within the 80-wave range of the C-band 50 GHz interval.

ESC FunctionSupport
PRBS FunctionTN52NS3/TN54NS3/TN55NS3/TN56NS3 WDM side supports PRBS function.
LPT functionNot supported
Error correction coding

TN11NS3/TN52NS3.

  • FEC coding is supported, complying with ITU-T G.709 recommendations.

  • Supports AFEC encoding, compliant with ITU-T G.975.1 recommendations.

TN54NS3.

  • Supports FEC coding and conforms to ITU-T G.709 recommendations.

  • Supports AFEC-2 encoding, compliant with ITU-T G.975.1 recommendations.

TN55NS3/TN56NS3.

  • Support HFEC encoding.

Description:

Veneers with different error correction codes cannot be docked.

Performance Surveillance and Alarm Monitoring
  • Provides BIP8 byte monitoring (Poisson mode or burst mode), which can locate line faults.

  • Provides the following monitoring functions: laser bias current monitoring, laser operating temperature monitoring, optical power monitoring, etc.

  • Support OTN performance monitoring and alarm monitoring functions.

  • Support CD and PMD performance monitoring function.

  • Provides B1 byte monitoring, which can locate line faults.

  • Provides B2 byte monitoring, which can locate line faults.

Description:

Only the TN54NS3 supports Poisson mode.

Only TN55NS3/TN56NS3 supports CD and PMD performance monitoring function.

Only TN56NS3 supports B1/B2 byte monitoring.

Relay Board
  • WDM side signals of TN11NS3/TN52NS3 single boards can be relayed by TN12LSXLR single board.

  • The WDM side signals of TN54NS3 single board can be trunked through other TN54NS3 single boards.

  • The WDM side signal of TN55NS3/TN56NS3 single board can be trunked through other TN55NS3/TN56NS3 single boards.

ALS FunctionNot supported
Test frame functionNot supported
IEEE 1588v2TN54NS3 supports BC and OC modes, TC and TC+OC modes are not supported.
Physical Layer Clocking (OTN)

Supported when the TN54NS3 backplane schedules ODU0/ODU1/ODU2/ODU2e signals.

Supported when the TN56NS3 backplane schedules ODU0/ODU1/ODU2/ODU2e/ODUflex signals.

Physical Layer Clock (OCS)

Supported by TN56NS3 only.

Optical Layer ASONSupported
Electrical layer ASON (OTN)Supported only by TN52NS3/TN54NS3/TN55NS3/TN56NS3
Electric layer ASON (SDH)Supported by TN56NS3 only

Description:

SDH ASON is not supported when the veneer is inserted in the T16 subrack.

Protection Mode

OTN Protection:

  • ODUk SNCP protection is supported.

  • Supports on-board 1+1 protection (realized with QCP or OLP or DCP single board).

  • Support ODUk ring network protection.

  • Support branch SNCP protection.

  • Support optical wavelength sharing protection.

SDH protection:

  • Supports SNCP protection.

  • Supports SNCTP protection.

  • Supports linear multiplexing segment protection.

  • Supports cyclic multiplexed segment protection.

Description:

Only the TN52NS3 supports optical wavelength sharing protection.

When the scheduling granule is ODUflex, ODUk ring protection and branch SNCP protection are not supported.

LoopbackSingle boardWDM side loopbackODU0/ODU1/ODU2 Channel LoopbacksODUflex Channel LoopbackVC-4 Channel Loopback
TN11NS3Support

ODU0/ODU1: Not Involved

ODU2: Supported

Not involvedNot involved
TN52NS3SupportSupportNot involvedNot involved
TN54NS3SupportSupportNot involvedNot involved
TN55NS3SupportSupportNot involvedNot involved
TN56NS3SupportSupportSupportSupport

Supported Protocols or Standards

Transmissive protocols or standards (no performance monitoring)

IEEE 802.3u

IEEE 802.3z

IEEE 802.3ae

IEEE 802.3ba

ITU-T G.707

ITU-T G.782

ITU-T G.783

ITU-T G.774.7

GR-253-CORE Synchronous Optical Network (SONET) Transport Systems: Common Generic

NCITS FIBRE CHANNEL PHYSICAL INTERFACES (FC-PI)

NCITS FIBRE CHANNEL LINK SERVICES (FC-LS)

NCITS FIBRE CHANNEL FRAMING AND SIGNALING-2 (FC-FS-2)

NCITS FIBRE CHANNEL BACKBONE-3 (FC-BB-3)

NCITS FIBRE CHANNEL SWITCH FABRIC-3 (FC-SW-3)

NCITS FIBRE CHANNEL - PHYSICAL AND SIGNALING INTERFACE (FC-PH)

NCITS FIBRE CHANNEL SINGLE-BYTE COMMAND CODE SETS-2 MAPPING PROTOCOL (FC-SB-2)

SMPTE 292M Bit-Serial Digital Interface for High-Definition Television Systems

ETSI TR 101 891 Professional Interfaces:Guidelines for the implementation and usage of the DVB Asynchronous Serial Interface (ASI)

SMPTE 259M 10-Bit 4:2:2 Component and 4fsc Composite Digital Signals - Serial Digital Interface

SMPTE 297-2006 Serial Digital Fiber Transmission System for SMPTE 259M, SMPTE 344M, SMPTE 292 and SMPTE 424M Signals

NCITS SBCON Single-Byte Command Code Sets CONnection architecture (SBCON)

ANSI X3.139 Information Systems - Fiber Distributed Data Interface (FDDI) - Token Ring Media Access Control (MAC)

ANSI X3.148 Information Systems - Fiber Distributed Data Interface (FDDI) - Token Ring Physical Layer Protocol (PHY)

ANSI X3.166 Information Systems - Fiber Distributed Data Interface (FDDI) Physical Layer Medium Dependent (PDM)

Protocol or standard for processing (with performance monitoring)

ITU-T G.805

ITU-T G.806

ITU-T G.709

ITU-T G.872

ITU-T G.7710

ITU-T G.798

ITU-T G.874

ITU-T M.3100

ITU-T G.874.1

ITU-T G.875

ITU-T G.808.1

ITU-T G.841

ITU-T G.8201

ITU-T G.873.1

ITU-T G.694.1

ITU-T G.707

ITU-T G.783

ITU-T G.774.1

ITU-T G.774.2

ITU-T G.774.3

ITU-T G.774.4

ITU-T G.774.5

ITU-T G.774.6

ITU-T G.774.9

ITU-T G.774.10

ITU-T G.825

ITU-T G.825

Description:

The TN11NS3/TN52NS3/TN54NS305 do not support trunk mode.

Table 2 NS3 Single Board Functions and Features (Trunk Mode)

Functions and FeaturesDescription
Basic FunctionUsed as an electrical relay station in the system to realize the electrical relay function of the corresponding optical signal.
Relay rate

OTU3: OTN service, the rate is 43.02Gbit/s.

OTU3e: OTN service, the rate is 44.58Gbit/s.

OTN function
  • The WDM side supports OTU3/OTU3e interfaces.

  • Adopts ITU-T G.709 recommended frame format and overhead processing.

  • OTU3 layer: supports SM function.

  • ODU3 layer: supports PM and TCM functions, non-invasive monitoring functions for PM and TCM.

WDM Specifications

Supports DWDM specifications of ITU-T G.694.1.

Wavelength Tunable Function

Supports wavelength tunable optical modules. Realizable.

  • Wavelength division side optical signals are adjustable in the 40-wave range at 100 GHz interval in C-band.

  • The wavelength of the optical signal is adjustable within the 80-wave range of the C-band 50 GHz interval.

ESC FunctionSupport
PRBS functionNot Supported
Error Correction Coding

TN54NS3.

  • Supports FEC coding and complies with ITU-T G.709 recommendations.

  • Supports AFEC-2 encoding, compliant with ITU-T G.975.1 recommendations.

TN55NS3/TN56NS3.

  • Support HFEC encoding.

Description:

Veneers with different error correction codes cannot be docked.

Performance Surveillance and Alarm Monitoring
  • Provides BIP8 byte monitoring (Poisson mode or burst mode), which can locate line faults.

  • Provides the following monitoring functions: laser bias current monitoring, laser operating temperature monitoring, optical power monitoring, etc.

  • Support OTN performance monitoring and alarm monitoring functions.

Description:

Only TN54NS3 supports Poisson mode.

ALS FunctionNot supported
Test frame functionNot supported
IEEE 1588v2Not Supported
Physical Layer ClockingNot Supported
Optical Layer ASONSupported
Electrical Layer ASONNot Supported
Protection ModeNot supported
LoopbackNot supported

Supported protocols or standards

Transmissive protocols or standards (no performance monitoring)

-Processing (with performance monitoring)

Protocol or standard for processing (with performance monitoring)

ITU-T G.805

ITU-T G.806

ITU-T G.709

ITU-T G.872

ITU-T G.7710

ITU-T G.798

ITU-T G.874

ITU-T M.3100

ITU-T G.874.1

ITU-T G.875

ITU-T G.808.1

ITU-T G.841

ITU-T G.8201

ITU-T G.694.1




Huawei TN54NS3T01 Purchase Price_Product Description_Hardware Description_Technical Parameters_Product Features-Huawei SDH Transmission Equipment Sales

Supply Optix OSN8800 TN54NS3T01 Quote_Agent Price_Sales Manufacturer_Product Supplier-Huawei SDH Transmission Equipment Sales

Online Ordering
Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML