Products
03030DKL Finished Board-OptiX OSN3500-SSN1IXCSA01-Infinite Cross Clock Board-No Extended Subracks
The parameters of the OSN3500 SSN1IXCSA board can be configured through the T2000 network management system.The parameters of the IXCSA board that need to be set through the network management are as follows: no external clock and SSM is not enabled, you need to give the following parameter configurations, the clock reference source, the tracking level of the clock source, the configuration of the external clock and SSM is enabled, the following parameter configurations are required, the clock reference source, the tracking level, the clock can work in the following modes: locking tracking level, the clock can work in the following modes: lock mode, hold mode, free oscillation mode, the type of external BITS: set the S1 byte, select the threshold of the clock inversion protection action. Dimensions: 40.0mm(W) x 235.2mm(D) x 261.4mm(H), Weight: 2.1kg, Maximum power consumption of the IXCSA board is 94W at room temperature (25°C).
OSN3500 IXCSA single board technical parameters and functions
Functions and features of the cross-connection unit of the IXCSA single boards
| Functions and features |
Description |
| Basic Functions |
- High-order crossover capacity: 200 Gbit/s
- Low-order crossover capacity: 40 Gbit/s
- Access capacity: 155Gbit/s
|
| Service Processing |
- Provide flexible service scheduling capability, support non-blocking full cross, support multicast and broadcast services.
- Provide communication function with other single boards.
- Supports microswitch to realize smooth protection inversion of cross boards.
- Supports SNCP protection at VC-4-4c, VC-4-8c, VC-4-16c, VC-4-64c, VC-4, VC-12, VC-3 and AU-3 levels.
- Supports VC-4-4c, VC-4-8c, VC-4-16c and VC-4-64c cascade services.
- Supports up to 40 linear multiplexing segment protection groups.
- Supports up to 12 ring multiplexing segment protection groups.
- Supports up to 8064 SNCP protection pairs.
- Supports up to 592 SNCMP protection pairs.
- Supports up to 512 SNCTP protection pairs.
|
| Protection Mode |
Supports 1+1 hot backup of single-board cross and clock units, and the protection mode is non-recovery by default. |
Clock Unit
The functions and characteristics of the clock unit of the IXCSA single board are shown in Table 2. Table 2 Functions and features of clock unit of IXCSA single board
| Functions and Characteristics |
Description of Clock Unit |
| Basic Functions |
Provides a standard system synchronization clock. |
| Other Functions |
- Supports processing of S1 byte for clock protection inversion.
- Supports the extraction, insertion and processing functions of SSM information and clock ID.
- Provides real clock RTC.
|
| Inputs and outputs |
Through AUX single board:
- Supports inputting 2 channels of 2048kHz or 2048kbit/s timing signals, and provides the function of selecting external timing sources.
- Supports output of 2-channel 2048kHz or 2048kbit/s timing signals.
|
OSN3500 IXCSA Single Board Tuning and Configuration
After selecting the correct single board, you need to test and configure the single board. It contains four parts: single-board hardware check, single-board configuration, single-board tuning and verification test.
Hardware Check
- Required: Check the hardware of the single board:
- The marking on the handle bar of the single board should be correct and clear.
- Veneer fasteners are secure and not loose.
- Veneer front and back of each device is complete, the surface is normal, no obvious signs of damage.
- Required: Confirmation of the slot and the installation of the main backup veneer.
- Required: Insert and place the veneer, the method of inserting and placing the veneer, please refer to the field replacement of the veneer. The veneer should be inserted along the guide channel to the bottom of the subrack and the veneer handle bar should be properly fastened.
- REQUIRED: Observe the status of each indicator of the veneer during and after the power-up process. See Device and Board Alarm Indicators for LED status descriptions.
- Required: Check the version matching relationship between the single board and the host, network management, to ensure that the single board version matching the use of error-free.
- Required: Check the micro-switch of the single board: if the handle bar of the main and backup cross boards are closed, pull open the handle bar of the main board to realize the reversal of the main and backup.
Single Board Configuration
- Add the logical single board, please refer to Add Single Board for specific operation.
- Network management configuration parameters, you need to configure the following main parameters:
- Clock synchronization status
- Clock source priority table
- External clock source output phase-locked source
- Clock source inversion
- Clock subnet settings
See Configuring Clocks for more parameters and specific configuration methods.
Single board tuning test
- Optional: test the frequency accuracy during free oscillation, see Testing the Frequency Accuracy during Free Oscillation.
- Optional: Test clock hold accuracy, see Testing Clock Hold Accuracy.
- Required: test cross-connect protection inversion, see Testing 1+1 Protection for Cross-Clocked Boards.
This product technical parameters and product features are provided by Shenzhen Guihang Network Technology Company Limited ( www.opticaltrans.com), please retain the reproduction. Huawei SDH Optical Transmission Equipment,SDH Transmission Equipment for sale