Protection requirements

The functional version of the OSN 3500 SXCSA veneer board is N1. The N1SXCSA supports the veneer-compatible replacement feature, which replaces the N1EXCSA or N1UXCSA veneer board. After replacement, the configuration and service status of the N1SXCSA single board are consistent with the N1EXCSA or N1UXCSA before replacement. It accomplishes 200 Gbit/s VC-4 high-order crossover, 20 Gbit/s VC-3/VC-12 low-order crossover, and 155 Gbit/s access capability.
OSN3500 SXCSA functions and features
The SXCSA single board supports functions and features such as service scheduling, clock input and output, etc. The functions and features of the SXCSA are shown below.
Types of cross and system control class boards supported by OptiX OSN3500
| Board Name | Board Description | Board Name | Board Description |
|---|---|---|---|
| N1GXCSA | Normal Cross Clock Board | N1IXCSA | Infinite Cross Clock Board |
| N1EXCSA | Enhanced Cross Clock Board | N1IXCSB | Infinite Intersection Clock Board (with Expansion Subrack) |
| N1UXCSA | Ultra-enhanced Crossed Clock Board | N1XCE | Expansion Subrack Cross Clock Board |
| N1UXCSB | Ultra-rugged Cross Clock Board with Expansion Subracks | N1GSCC | Intelligent System Control Board |
| N1SXCSA | Super Cross Clock Board | N3GSCC | Intelligent System Control Board |
| N1SXCSB | Super Cross Clock Board (with Expansion Subrack) | N4GSCC | Intelligent System Control Board |
| N2PSXCSAa | Super Dual Plane Cross Clock Board (supports packet features) | - | -a: N2PSXCSA can only be used with N4GSCC. |
|
a: N2PSXCSA can only be used in conjunction with N4GSCC, the board does not support packetized features in this version, if you need to support packetized features, you need to upgrade the board software and host software to the appropriate software version. |
|||
OSN3500 SXCSA Technical Specifications
SXCSA single-board specifications include crossover capability, clock access capability, single-board size, weight and power consumption.
OSN3500 SXCSA Crossover Capability
The crossover capacity of the SXCSA single board is as follows:
Clock access capability
The clock access capability of the SXCSA single board is as follows:
Mechanical specifications
The mechanical specifications of the SXCSA single board are as follows:
Power consumption
The maximum power consumption of SXCSA veneer is 63W at room temperature (25°C).