Table 1 Optix OSN2500 Linear Multiplexing Segment Protection Parameters
Protection Type Recovery Type Rewind protocol Rewind time Waiting time for recovery Rewind conditions (meet one condition to revert)
1+1 single-ended reversal Non-recovery Not required ≤50ms -R_LOS
  • R_LOS
  • R_LOF
  • MS_AIS
  • B2_EXC
  • B2_SD (optional)
  • Forced Rewind
  • Manual inversion
  • Practice inversion
1+1 single-ended inversion Recovery Not required 600s
1+1 double-ended inversion Non-Recovery APS Protocol 1+1 Dual-Ended Rewind
1+1 Double-Ended Rewind Recovery APS Protocol 600s
1:N double-ended inversion (N≤14) Recovery APS protocol 600s

Table 2 Optix OSN2500 multiplexed segment protection ring parameters
Protection Type Recovery Type Rewind mode Rewind time Waiting time for recovery Rewind condition (meet one condition to rewind)
Two-fiber bi-directional protection Recovery

Forced reversal

Manual reversal

Practice reversal

≤50ms 600s
  • R_LOS
  • R_LOF
  • MS_AIS
  • B2_EXC
  • B2_SD (optional)
  • Forced Rewind
  • Manual inversion
  • Practice Rewind
Two-fiber unidirectional protection Recovery

Forced reversal

Manual Reversal

Practice Reversal

Quad Fiber Bidirectional Protection Recovery

Forced Ring Reversal

Manual Ring Reversal

Practice Ring Reversal

Forced Segment Reversal

Manual Zone Reversal

Practice Zone Reversal


Table 3 Optix OSN2500 SNCP protection function parameters
Protection Type Recovery Type Rewind time Waiting time for recovery Rewind condition (one condition is met to revert)
SNCP Recovery ≤50ms 600s
The inversion conditions for VC4 level SNCP are as follows:
  • R_LOS
  • R_LOF
  • R_LOC
  • MS_AIS
  • B2_EXC
  • AU_AIS
  • AU_LOP
  • B3_EXC (optional)
  • B3_SD (optional)
  • HP_UNEQ (optional)
  • HP_TIM (optional)
The inversion conditions for VC3 level SNCP are as follows:
  • TU_LOP
  • TU_AIS
  • B3_EXC (optional)
  • B3_SD (optional)
  • MW_LOF (only if the IF board is a line board)
  • MW_LIM (only if the IF board is used as a line board)
The inversion conditions for the VC12 level SNCP are as follows:
  • TU_LOP
  • TU_AIS
  • BIP_EXC (optional)
  • BIP_SD (optional)
  • MW_LOF (only if the IF board is a line board)
  • MW_LIM (only if the IF board is used as a line board)
Non-recovery -


Supply Optix OSN2500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply Optix OSN2500_Troubleshooting_Installation_Tuning_Technical Specification_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板