18529092692

Home >> News
News
SSN3EGS2 port mode error causing reported MOD_TYPE_MISMATCH
| 2025-11-21|Back

Problem Description
A new bureau project, equipment model: OSN 3500, version: V100R010C03SPC203 (5.21.20.54), U2000 network management (V1R9) configuration is completed N3EGS2 single-board Ethernet services, the two ends of the downstream PCs, each other ping each other's IP address, the communication is normal, but reported MOD_TYPE_MISMATCH alarm. MISMATCH alarm.
Alarm Information
MOD_TYPE_MISMATCH, parameters: 0X01,0X00,0X01,0XFF,0XFF
Processing
1, the first two ends of the downlink PC, each other ping each other's IP address, communication is normal, indicating that the actual SFP module communication function is normal, suspect that the single board or the master misreported alarm, reset the N3EGS2 and the master board, and then query the alarm still exists; other slots are not configured with data, there is no alarm reported on the GE optical port N3EGS2 and the alarm reported on the N3EGS2 of the GE electrical port single board. After switching, the alarms of the two single boards have disappeared, ruling out the problems of single boards and modules, and suspecting the problems of port parameter settings.
2、According to the reported MOD_TYPE_MISMATCH, parameters: 0X01,0X00,0X01,0XFF,0XFF, alarm parameter 1#PORT reported alarm, please engineer selected EGS2 single board, in the Network Element Manager-Function Tree-Configuration-Ethernet Interface Management-Ethernet Interface-External Port, check the port logic type for SDH optical port, change the port logic type for SDH optical port to SDH optical port, and change the port parameter setting for SDH optical port. SDH optical port to SDH electrical port, the alarm disappears.
Root Cause
For single boards that support GE optical port and GE electrical port, you can configure the port logical type in the network management, and the default port logical type of U2000 network management is SDH optical port, the engineer did not change the port logical type when enabling the port and configuring the port working mode, and the actual physical module is GE electrical port, and after the data is sent to the single board, the single board detects that the port module does not match, and therefore this alarm is reported.
Recommendation and Summary
1, NG-SDH supports GE optical port and GE electrical port boards: N3EGS2, N1EGS4, N4EGS4, N1EMS2, N1EMS4, N2EGT2
2, when setting the port attributes of the boards that support GE optical and GE electrical ports, be sure that the logical type of the modified ports is the same as that of the actual configuration.


Supply OSN3500 SSN3EGS2_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH Transmission Equipment Sales
OSN3500 SSN3EGS2_Troubleshooting_Installation and Testing_Technical Specifications_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板