Problem description
The new OSN 3500 in the previous partner upgrade project was upgraded from 5.21.18.12 to 5.21.18.50, and it was found that the upgrade of two sets of OSN 3500 cross boards was abnormal, prompting the single board to return the error : the file length exceeded the limitation. (Error code : 12-32775), other single boards, other equipment OSN 3500XCS can be upgraded successfully. The upgrade tool adopts the latest TOOLKIT R4 version, board pole loading mode.
Alarm information
1. There is no alarm on the device;
2、Toolkit R4 on the prompt: prompt single board return error : file length exceeds the limit. (Error code : 12-32775)
Processing
1. Analyzing from the alarm, it should be caused by insufficient space of the single board, suggesting the partner to remove the original software ( xcssoft.hwx, ne.ini, extbios.hwx ) which need to be upgraded, as well as the software which is loaded abnormally, and reload it through the navigator command :sftm-delete-file. The fault still reappears.
2, engineers just arrived at the scene, check the toolkit upgrade log, found that ne.ini, extbios.hwx can be loaded successfully, but xcssoft.hwx failed to load, through the navigator upgrade is also the same.
3, check the remaining space of the single board, found that the problematic network elements in the absence of loading software than the normal upgrade of the remaining space of the successful network elements are less, and the space than the xcssoft.hwx1336939 size is even smaller as follows:
Abnormal network elements:
#4-803:szhw [803-Kai County Hot Springs Middle School ][][2009-12-01
11:25:06+08:00]>
:sftm-get-freespace:10, "ofs1"
RESULT-INFO
BOARD_ID DEV_NAME FREE_SPACE
10 ofs1 88064
Total records :1
Normal network elements:
#9-2012:szhw [2012-Wushan ][][2009-12-01
11:30:15+08:00]>
:sftm-get-freespace:9, "ofs1"
RESULT-INFO
BOARD_ID DEV_NAME FREE_SPACE
9 ofs1 11921408
4, it can be seen that the abnormal network element must have space is abnormal data exhaustion, view ofs1 under the file, only log under the log can be more assured of deletion, backup log under all the log (can be directly copied through the local FTP, remote data collection tools or navigator collection of black box and other data) to the portable after the command line : sftm-delete- file to delete all files under ofs1, :sftm-get-freespace to view, the space is greatly released.
5, reload successfully.
Root cause
Upgrading exceptions can be narrowed down according to the error code to locate the scope, in this case the file length exceeded the limit. (Error code : 12-32775), suggesting that the lack of space is a possible cause, so decisively take the corresponding space release is one of the main ways.
Suggestions and Summary
1、Checking the Swift error code can narrow down the scope of fault localization;
2、Upgrade the software correctly, according to the error code decisively take the code of the prompt operation.
3, the later upgrade also appeared OSN 7500XCS, OSN3500 SSN2PQ1A similar situation, according to the above way can solve the problem.
4, the current OSN host, single-board software are relatively large, if the upgrade appears in the file length exceeds the limit. (Error code : 12-32775), you can directly delete the file under the log, if necessary, you can first backup ( FTP, data collection, navigator, etc.).


Chinese