Problem Description
2-endOSN3500, each configured with 2PEX1 and PEG16 single boards, but neither of them can query the power performance of the transceiver, host version 5.21.30.12,T2000V2R7C03 network management
Alarm message
None
Processing
1、Check the performance monitoring settings of the network element, they are all set to on, and you can check the temperature and other performance of the network element.
2、Check the performance monitoring status of the single board in the light-emitting power performance monitoring object enable settings, has been enabled
3、All single boards can not query the optical power, you can rule out single board problems
4、Consult the company's R & D, told that the host version does not support, need to upgrade to 5.21.30.14
5、After upgrading to 5.21.30.14, the problem is solved.
Root cause
1、Performance monitoring is not turned on
2、Single board problem
3、Functions not supported
Recommendation and Summary
OSN3500 MSTP+ products need to be upgraded to 5.21.30.14 in order to query the transmitting power of PEX1 and PEG16 single boards.