Problem Description

The command line configuration of OSN3500 mstp+ version feature is different from the previous existence, the configuration is modular and all configurations should have a first and last , see the following example.

Alarm message

None

Processing

Configure OSN3500 TPS protection as follows, with the beginning and end of a completed configuration indicated by :trans-begin:locked, trans-commit:"".

:trans-begin:locked

:cfg-add-board:9,ssn1psxcs

:cfg-add-board:1&&5,ssn1pq1

:cfg-add-board:13&&16,ssn1pq1

:trans-commit:""

:trans-begin:locked

:cfg-add-tpspg:1,8

:cfg-set-tpsbdmap:1,0,1

:cfg-set-tpsbdmap:1,1,2

:cfg-set-tpsbdmap:1,2,3

:cfg-set-tpsbdmap:1,3,4

:cfg-set-tpsbdmap:1,4,5

:cfg-set-tpsbdmap:1,5,13

:cfg-set-tpsbdmap:1,6,14

:cfg-set-tpsbdmap:1,7,15

:cfg-set-tpsbdmap:1,8,16

:trans-commit:""

If you don't follow the above requirements, or the network management version does not match, the following error is reported:

failed! cmd:0x8560 error:0x9a3e NSERR_CFG_PG_NOT_COMPLETE

Root Cause

Optix OSN3500 new release features.

Recommendations and Summary

None


Sell Huawei OSN3500_Product Quotation_Sales Manufacturer_Product Features_Product Description_Huawei SDH Transmission Equipment Sales
Supply Huawei OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板