18529092692

Home >> News
News
Optix OSN3500 SSN1EMS4 Unable to add EFF8 or EFT8 interface boards
| 2025-11-21|Back

Problem Description

At a newly opened site, after adding EMS4 board in OSN3500 16 slot, engineers are unable to add EFF8 or ETF8 board in 36 slot (interface board slot), and the network management prompts the error: slot number is illegal, error code 38663.

Alarm message

Slot number is illegal, error code 38663.

Processing

1. Check the product manual, which clearly states that after adding EMS4 board in slot 16, you can add EFF8 or ETF8 interface board in slot 35 or 36.

2、Set the network management to pre-configuration, and you can add the interface board in slot 35 or 36 without any problem.

3、Return data R&D analysis: the version code is wrong, resulting in the EFF8/EFT8 single board can only be added on slots 19, 21, 23, 25, 29, 31, 33, 35, and can not be added on other slots.

4、After confirming, this problem exists from version 5.21.16.xx to 5.21.18.44 , to solve this problem, we need to upgrade to version 5.21.18.50 and above.

Root Cause

1. The EMS4 single board does not support adding an interface board in slot 36.

2、Network management or host defect.

Solution

Recommendation and Summary

None


Sales OSN3500 SSN1EFF8_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH Transmission Equipment Sales
Supply OSN3500 SSN1EFF8_Troubleshooting_Installation and Testing_Technical Specifications_Technical Parameters_Huawei SDH Transmission Equipment Sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板