Optix OSN2500SSQ2CXL16_SSQ5CXLL16 Single Board Functions and Features
The CXL16 single board supports SDH signal processing, communication control, service scheduling, clock input and output, and other functions and features.
1. SDH Processing Unit
The functions and features of SDH processing unit of CXL16 single board are shown in Table 1.
|
Table 1 Functions and features of SDH processing unit of CXL16 single-board |
|
|
Function and Characteristics |
Description |
|
Basic Functions |
Receive and transmit 1 channel STM-16 optical signal. |
|
Optical Interface Specifications |
I-16, S-16.1, L-16.1 and L-16.2 standard optical modules |
|
Optical module specifications |
Support optical module information detection and query. Support laser on and off setting and laser auto shutdown function. |
|
Service Processing |
Support VC-12/VC-3/VC-4 services and VC-4-4c, VC-4-8c, VC-4-16c cascade services. |
|
Overhead processing |
Supports the processing of segment overhead for STM-16 signals. Supports the processing of channel overhead (transparent transmission and termination) and the setting and querying of J0/J1/C2 bytes. |
|
Alarm and Performance |
Provides rich alarms and performance events for easy management and maintenance of the device. |
|
Protection Mode |
Supports two-fiber, four-fiber ring multiplexing segment protection, linear multiplexing segment protection, SNCP (Sub-Network Connection Protection) protection. |
|
Maintenance Characteristics |
Supports inner loopback and outer loopback functions at the optical port level. Supports soft reset and hard reset, soft reset does not affect the service. Support query function of single board manufacturing information. Support the online loading function of FPGA. Support smooth upgrade of veneer software. |
2. System control and communication unit
CXL16 single-board system control and communication unit functions and features shown in Table 2.
|
Table 2 CXL16 single-board system control and communication unit functions and features |
|
|
Functions and Characteristics |
Description |
|
Basic Functions |
Realize the configuration and scheduling functions of equipment services, monitor service performance, and collect performance events and alarm information. |
|
Interface Specifications |
Provides 10M/100M compatible Ethernet network management interface. Provides F&f port for COA management, which is led out through the auxiliary interface board. Provides one 10M/100M Ethernet interface for communication between the single boards. Provide one 10M Ethernet interface for communication between main/standby master boards. Provide RS232 interface OAM port for connecting with PC or workstation, and support RS232 DCE Modem for remote maintenance, which is led out through the auxiliary interface board. |
|
DCC Processing Capability |
Provides 40-channel DCC processing capability. |
|
Fan alarm management |
Provides fan alarm management function. |
|
PIU Management |
Provide the presence detection function of the PIU of the power access board and the failure detection function of the lightning protection module in the PIU. |
|
Protection Mode |
The system control and communication units support 1+1 hot backup. |
3. Cross-connection unit
The functions and characteristics of the cross-connection unit of the CXL16 single board are shown in Table 3.
|
Table 3 Functions and features of cross-connection unit of CXL16 single board |
|
|
Function and Characteristics |
Description |
|
Basic function |
Completes VC-4 non-blocking full crossover at 20 Gbit/s and VC-12/VC-3 non-blocking full crossover at 20 Gbit/s. |
|
Fast Emergency Channel |
Provide two 4M HDLC fast emergency channels for realizing MSP, SNCP inversion and other functions. |
|
Service Processing |
Realize flexible scheduling of services, including cross and broadcast, etc. Adding or deleting services does not affect other services. Supports SNCP protection at VC-3 and VC-12 levels. Supports cascading services VC-4-4c, VC-4-8c, VC-4-16c. |
|
Protection Mode |
Cross-unit supports 1+1 hot backup, and the protection mode is non-recoverable inversion by default. |
4.Clock Unit
The functions and characteristics of the cross-connect unit of the CXL16 single board are shown in Table 4.
|
Table 4 Functions and features of cross-connect unit of CXL16 single board |
|
|
Function and Characteristics |
Description |
|
Basic Functions |
Provides a standard system synchronization clock. |
|
Other Functions |
Support SSM information, clock ID extraction, insertion and processing functions. |
|
Input/Output |
Supports inputting 2 channels of 2048kHz or 2048kbit/s timing signals, and provides the function of selecting external timing sources. Supports outputting 2-channel 2048kHz or 2048kbit/s timing signals. |