MA5800-X15exterior structure
The MA5800-X15 service frame has 20 slots and is equipped with a fan frame on the top. The service frame is fixed in the cabinet by lugs.
Introducing the MA5800-X15Physical Parameters Dimensions and Weight
MA5800-X15 business frame size and weight parameter table
|
Item |
Numerical value |
|---|---|
|
Physical dimensions with lugs (W×D×H) |
482.6mm×287mm×486mm |
|
Physical dimensions without lugs (W×D×H) |
442mm×287mm×486mm |
|
Maximum weight (with lugs) |
35kg |
Power Supply Parameters for MA5800-X15 Business Frame
|
Item |
Parameter |
|---|---|
|
Power supply mode |
DC (dual power backup) |
|
Rated Voltage |
-48V/-60V |
|
Operating Voltage Range |
-38.4V to -72V |
|
Maximum input current per circuit |
60A |
MA5800-X15 Service Frame Power Consumption Parameter Table (Unit: W)
|
Typical Configuration |
Static power consumption |
Maximum Power Consumption |
Typical Power Consumption |
Single Board Configuration |
|---|---|---|---|---|
|
GPON |
531 |
1242 |
886.5 |
h901mplb*2+h901oghk+h901pila*2+h901fmla+h901gphf*14 |
The power consumption of the business frame is tested under the following conditions:
- Operating voltage: -53.5V DC.
- Room temperature: 25°C.
- Static power consumption: all ports do not carry any load, and optical ports do not insert optical modules.
- Maximum power consumption: all ports carry 100% load.
- Typical power consumption: half of the sum of static and maximum power consumption.
MA5800-X15 ServicesSlot Configuration
The MA5800-X15 service frame provides 20 slots, including 2 main control board slots, 2 power board slots, 1 general-purpose interface board slot, and 15 service board slots.The backplane supported by the MA5800-X15 service frame is H901BPIB.Figure 1 MA5800-X15 service frame single board configuration diagram

MA5800-X15 slot description
|
Slot Classification |
Slot |
Configurable Single Board |
Remarks |
|---|---|---|---|
|
Main control board slot |
8, 9 |
Main control board |
Two slots need to be configured with the same master control board, requiring dual master control boards. |
|
Power supply board slot |
18, 19 |
Power supply board |
-Power supply board |
|
General Purpose Interface Board Slots |
0 |
General Purpose Interface Board |
-General Purpose Interface Board |
|
Business board slots |
1 to 7, 10 to 17 |
|
|
The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain! Our company specializes in Huawei SDH optical transmission equipment,SDH transmission equipment sales.