18529092692

Home >> News
News
MA5800-X15 product appearance structure and equipment slot introduction
| 2025-11-21|Back

MA5800-X15exterior structure

The MA5800-X15 service frame has 20 slots and is equipped with a fan frame on the top. The service frame is fixed in the cabinet by lugs.


Introducing the MA5800-X15Physical Parameters Dimensions and Weight

MA5800-X15 business frame size and weight parameter table

Item

Numerical value

Physical dimensions with lugs (W×D×H)

482.6mm×287mm×486mm

Physical dimensions without lugs (W×D×H)

442mm×287mm×486mm

Maximum weight (with lugs)

35kg

Power Supply Parameters for MA5800-X15 Business Frame

Item

Parameter

Power supply mode

DC (dual power backup)

Rated Voltage

-48V/-60V

Operating Voltage Range

-38.4V to -72V

Maximum input current per circuit

60A

MA5800-X15 Service Frame Power Consumption Parameter Table (Unit: W)

Typical Configuration

Static power consumption

Maximum Power Consumption

Typical Power Consumption

Single Board Configuration

GPON

531

1242

886.5

h901mplb*2+h901oghk+h901pila*2+h901fmla+h901gphf*14

Description:

The power consumption of the business frame is tested under the following conditions:

  • Operating voltage: -53.5V DC.
  • Room temperature: 25°C.
  • Static power consumption: all ports do not carry any load, and optical ports do not insert optical modules.
  • Maximum power consumption: all ports carry 100% load.
  • Typical power consumption: half of the sum of static and maximum power consumption.

MA5800-X15 ServicesSlot Configuration

The MA5800-X15 service frame provides 20 slots, including 2 main control board slots, 2 power board slots, 1 general-purpose interface board slot, and 15 service board slots.The backplane supported by the MA5800-X15 service frame is H901BPIB.Figure 1 MA5800-X15 service frame single board configuration diagram


MA5800-X15 slot description

Slot Classification

Slot

Configurable Single Board

Remarks

Main control board slot

8, 9

Main control board

Two slots need to be configured with the same master control board, requiring dual master control boards.

Power supply board slot

18, 19

Power supply board

-Power supply board

General Purpose Interface Board Slots

0

General Purpose Interface Board

-General Purpose Interface Board

Business board slots

1 to 7, 10 to 17

  • Uplink Interface Board
  • Service Boards
  • Supports mixing and matching of different service boards.
  • Uplink can be master uplink or uplink interface board uplink, master uplink is recommended.

The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain! Our company specializes in Huawei SDH optical transmission equipment,SDH transmission equipment sales.


Sales MA5800_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply MA5800_Troubleshooting_Installation_Tuning_Technical Index_Technical Parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板