OSN1500 Network Element Upgrade Exception (MSTP) Handling Procedure
| 2025-11-21|Back

Determine whether the main control is faulty

If it is a master control failure, proceed as follows.

Check the PROG indicator of the single board on site. If it flashes frequently and abnormally, or the PROG red light is always on, directly unplug the single board and observe whether it can start work normally. If it cannot start normally, replace the main control board.

If the above operation is ineffective, check whether the master control slot is inverted.

After normal startup, check whether the configuration is lost. If it is lost, the non-ASON or packetized network element performs network management configuration download, and the ASON or packetized network element performs database repair, considering several options for parallel operation, such as network element database, network management script to configuration script, and historical patrol data to configuration script.

If it is not a master control failure, turn to determine whether the cross and service veneer failures.

Determine whether the crossover and service boards are faulty

Determine whether the crossover and service boards are unable to start as follows.

The single board cannot start normally on line, the network management display is gray or the network management fails to query the single board information.

Business interruption.

Check the BIOS version for errors.

For NGSDH products SSN1GXCSA, SSN1EXCSA, SSN1UXCSA, SSN1UXCSB veneer boards, check whether the base BIOS before upgrade is version 2.13 and before, and the extended BIOS of the target version is version 2.32 and after.

Verify that the base BIOS software is not loaded first when upgrading.

Try to reload the BIOS software, use the DC tool to create a board-level software loading task, select the basic BIOS of the crossover board to load, refer to the simulation package for the way, activate the crossover board, and wait for 5 minutes to check whether the veneer board is online.

Replace the veneer spare parts.

If it is not a crossover and the service veneer cannot be started, turn to determine whether the service configuration has been changed or lost.

Determine whether the business configuration has been changed or lost

If it is a configuration loss failure, follow the steps below.

Return the database, network management scripts, inspection scripts, and other information backed up before the upgrade.

For non-ASON or packetized network elements, download the network management configuration (provided that the network management has not uploaded the network management configuration after the configuration of the network element has changed or been lost); ASON or packetized network elements need to make configuration databases or configuration scripts to the current network for recovery, and at the same time as Huawei engineers of the United System do the recovery configuration, the field engineers can try to cut through the service at the site to manually restore some of the configurations.

If it is not a configuration loss failure, turn to determine whether the branch board veneer service interruption.

Determining whether a branch board single board service is interrupted

Judgment method: downstream low-order service interruption, no alarm or LP_TIM alarm at this end.

If the NGSDH product is upgraded from the product before R8 to R8 and later versions; turn the LP_TIM alarm monitoring on to eliminate the LP_TIM alarm.


This chapter of related technical information and SDH equipment troubleshooting process is collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), reproduced please retain! Our company specializes in Huawei SDH optical transmission equipment, SDH transmission equipment sales.


Sell Optix OSN3500_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Optix OSN3500_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板