18529092692

Home >> News
News
Optix OSN9800 Intelligent Optical Transport Platform Product Specifications U64/U32/U16
| 2025-11-21|Back

OptiX OSN9800 U64/U32/U16 series subracks are the new generation of high-capacity, intelligent OTN products with packetization function for 100G and super 100G, which are applicable to various network levels such as super trunk, backbone and metro.

The specifications are as follows:

Indicator OptiX OSN 9800 U64 Standard OptiX OSN 9800 U32 Standard OptiX OSN 9800 U16 OptiX OSN 9800 U32 Enhanced
Product Appearance
点击放大
点击放大 点击放大
Subrack Dimensions 600 mm (W) × 600 mm (D) × 2200 mm (H) (integrated frame and cabinet) 498 mm (W) × 295 mm (D) × 1900 mm (H) (without cabinet) 442 mm (W) × 295 mm (D) × 847 mm (H) (without cabinet) 498 mm (W) × 295 mm (D) × 1900 mm (H) (without cabinet)
Adaptable cabinetsa Integrated frame cabinet, no cabinet configuration required ETSI 300/600, e.g. N63B, N66B
  • ETSI 300/600, e.g. N63B, N66B
  • 19-inch cabinet
ETSI 300/600, e.g. A63B
Number of slots for business boards 64 32 14 32
Cross Optical Layer N/A
Electrical layer
  • 25.6 Tbit/s ODUk (k=0, 1, 2, 2e, 3, 4, flex)

  • 12.8 Tbit/s Packet service

  • 5.12 Tbit/s VC-4

  • 80 Gbit/s VC-3/VC-12
  • 12.8 Tbit/s ODUk (k=0, 1, 2, 2e, 3, 4, flex)

  • 6.4 Tbit/s Packet service

  • 2.56 Tbit/s VC-4

  • 80 Gbit/s VC-3/VC-12
  • 5.6 Tbit/s ODUk (k=0, 1, 2, 2e, 3, 4, flex)

  • 2.8 Tbit/s Packet service

  • 1.12 Tbit/s VC-4

  • 80 Gbit/s VC-3/VC-12
  • 32 Tbit/s ODUk (k=0, 1, 2, 2e, 3, 4, flex)

Maximum number of waves
  • fixed-grid: 96 waves @ 50 GHz
  • flex-grid: maximum wave count and FLEX channel width dependent
Wavelength spacing
  • Fixed spacing: 50 GHz/100 GHz
  • flex-grid: wavelength spacing can be set
Center wavelength range DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1)
Maximum single-channel rate 400 Gbit/s (OTUC4)
Supported service types SDH/SONET, Ethernet, SAN, OTN, Video
Packet service capability
  • Supports E-Line/E-LAN (MEF) and VPWS/VPLS (IETF)
  • Supports MPLS-TP
  • Number of MPLS tunnels: 64x1024
  • Total number of PWs: 64x1024
  • Number of E-Lines: 32x1024
  • Number of E-LANs: 8x1024
N/A
Line rate 10 Gbit/s, 40 Gbit/s, 100 Gbit/s, 200 Gbit/s, 400 Gbit/s 100 Gbit/s, 200 Gbit/s, 400 Gbit/s
Supported pluggable optical modules eSFP, SFP+, XFP, CFP, CXP, CFP2, QSFP28 eSFP, SFP+, CFP, CFP2, QSFP28
Network Topology Point-to-point, chain, star, ring, ring with chain, tangent ring, intersecting ring, and mesh networking
Redundancy and Protection Network level protection (OTN) Customer-side 1+1 protection, on-board 1+1 protection, LPT, ODUk SNCP, tributary SNCP, port-level M:N protection Customer-side 1+1 protection, on-board 1+1 protection, LPT, ODUk SNCP, tributary SNCP
Network level protection (packet) ERPS, LAG, MC-LAG, LMSP, MC-LMSP, MRPS, PW APS, MC-PW APS, Tunnel APS, LPT N/A
Network Level Protection (OCS) Linear multiplexing segment protection, SNCP N/A
Device-level protection Power supply redundancy, fan redundancy, cross redundancy, communication control and clock unit redundancy
Optical power management ALS, AGC, ALC, APE, IPA, Raman system IPA
Synchronization
  • Synchronous Ethernet
  • IEEE 1588v2
  • ITU-T G.8275.1
N/A
ASON Power Layer ASON
TSDN
  • Online Service Delivery
  • Survivability Analysis
  • BOD
  • IP+Optical Collaboration
Submarine Cable Features Supports extended C-band submarine cable applications.
Power Supply
  • Standard operating voltage: -48V DC/-60V DC
  • Voltage operating range:
    • -48V DC: -40V to -57.6V
    • -60V DC: -48V to -72V
Device operating environment
Subframe temperature:
  • Long-term operation: 5°C to 40°C
  • Short-term operationb : -5℃~45℃
Sub-shelf relative humidity:
  • Long-term operation: 5%~85
  • Short-term operationb:5%~90%
Sub-shelf temperature:
  • Long-term operation: 5℃~40℃
  • Short-term operationb:-5℃~50℃
Sub-shelf relative humidity:
  • Long-term operation: 5%~85
  • Short-term operationb:5%~90%
Sub-shelf temperature:
  • Long-term operation: 5℃~40℃
  • Short-term operationb:-5℃~45℃
Sub-shelf relative humidity:
  • Long-term operation: 5%~85
  • Short-term operationb:5%~90%
Mean Time to Repair (MTTR) 4 hours
Mean Time Between Failure (MTBF) 66.83 years

a: ETSI/19inch standard only defines a part of the cabinet size, so the distance from the cabinet column to the door plate of each cabinet manufacturer is different, and the details of the cabinet size requirements of different subracks should be referred to the detailed introduction of subracks.


The related technical information in this chapter and the troubleshooting process of SDH equipment are collected and organized by Shenzhen Optical Transmission Network Technology Company Limited (www.opticaltrans.com), please retain the reproduction! Our company specializes in the sale of Huawei SDH optical transmission equipment,SDH transmission equipment.


Sell Huawei OSN9800_Product Quotation_Sales Manufacturer_Product Characteristics_Product Description_Huawei SDH transmission equipment sales
Supply Huawei OSN9800_Troubleshooting_Installation and testing_Technical specifications_Technical parameters_Huawei SDH transmission equipment sales

Contact Us
Name:Mr Zhang
Phone:18529092692
Tel:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Contact
18529092692
Phone:18529092692
Email:info@opticaltrans.com
Address:Cuiguang 1st Distriuct Buiding 8th, Shenzhen, Guangdong Province
Follow Us
Otrans Technology is a high-tech enterprise deeply engaged in optical transmission and network communication equipment, specializing in...
Copyright © 2025 Otrans all right reserve XML 网站模板